57
STEL s.r.l.
– Via del Progresso n° 59 – 36020
Loc. Castegnero (VICENZA) - ITALY
TEL. +39 0444 639525 (central.) – +39 0444 639682 (comm.)
FAX +39 0444 639641 – E-mail: stel @ stelgroup.it
http: www.stelgroup.it
MAX 503 & MAX 503 IP44
COD. 6914500030
5.4
5.4
5.4
5.4 ---- V.R.D.
V.R.D.
V.R.D.
V.R.D. (ACTIVE ONLY FOR THE ELECTRODE FUNCTION)
(ACTIVE ONLY FOR THE ELECTRODE FUNCTION)
(ACTIVE ONLY FOR THE ELECTRODE FUNCTION)
(ACTIVE ONLY FOR THE ELECTRODE FUNCTION)
5.5
5.5
5.5
5.5 ---- V.R.D. MANAGEMENT
V.R.D. MANAGEMENT
V.R.D. MANAGEMENT
V.R.D. MANAGEMENT
The initials V.R.D. stand for VOLTAGE REDUCTION DEVICE, which is a system
for reducing the no-load voltage.
When the V.R.D. is installed in a welding machine it reduces the maximum no-
load voltage to a safety voltage which is normally less than 20V.
- The V.R.D. is used as an additional aid for operator safety.
- The procedures for safety at work must always be carried out with attention.
5.6
5.6
5.6
5.6 ---- ACTIVATING THE V.R.D.
ACTIVATING THE V.R.D.
ACTIVATING THE V.R.D.
ACTIVATING THE V.R.D.
1) Switch on the generator.
2) Hold down the button
V
(ref.5 page 51-52) on the front panel of the machine for
about 3 seconds, then release the button; the arc lit led (ref.2 page 51-52) blinks
(V.R.D. FUNCTION ON) (Vout 20V).
VRD mode remains on even after switching the machine off and on again.
5.7
5.7
5.7
5.7 ---- EXCLUDING THE V.R.D.
EXCLUDING THE V.R.D.
EXCLUDING THE V.R.D.
EXCLUDING THE V.R.D.
1) Switch on the generator.
2) Hold down the button
V
(ref.5 page 51-52) on the front panel of the machine for
about 3 seconds, then release the button; the arc lit led (ref.2 page 51-52)
remains lit with a fixed light (V.R.D. FUNCTION excluded).
VRD mode remains excluded even after switching the machine off and on again.
TECHNICAL
DESCRIPTION
ENGLISH