STEIN300_Umsetzer_04_GB.doc / 03.2020
21
CAUTION
After installing the 180° transfer unit you must also install the supplied protective
plates!
CAUTION
Do not place the 180° transfer unit in service without the installation kit!
i
To install the 180° transfer unit use the special offset wrench from
Stein
Automation
.
i
Prior to installing the 90° transfer unit the transverse section braces must be must be
mounted.
i
Through the installation of:
- Stoppers
- P accessories and the corresponding
- Installation kit
the transfer unit attains its full functional capability.
Align the slots of the slotted screws parallel to the belt profile.
The slotted screws are now unlocked.
Guide the transfer unit from below vertically between the belt profiles.
Secure the transfer unit from falling with suitable aids or with additional assisting
personnel.
Position the transfer unit correctly.
Rotate the slotted screw by 90° to the belt profile with the screwdriver. The slotted
screws are now locked.
Tighten the locknuts of the slotted screws.
i
In order to ensure correct functioning, all the directly bordering switches and stoppers
must be correctly adjusted.
i
Please refer to chapter 10 for the installation dimensions and other dimensions.
5.4
Fitting the stopping devices
i
Further information can be found in the technical description
“
Stopping Device
”
(SE).
Please also see the service video
“
Replacing the stopper
”
.