SM-WC-
LR Li’l Runner (HS)
Li’l Runner (HS) Operator’s Manual
39
5.13. Vacuum unit
When used with a vacuum pump, the vacuum unit allows clamping a flexible track-
way to non-ferromagnetic surfaces. The holding force of the vacuum unit is 1400 N
(300 lbs) at gauge pressure of
–0.7 bar (–10 psig) and atmospheric pressure at sea
level. The force decreases with increase in height above sea level. To increase the
holding force of the trackway, use more vacuum units if possible.
Make sure that the ambient temperature is between
–20°C and 200°C (–6°F and
392°F). Keep the flame at least 100
mm (4″) away from the vacuum pads.
Use a torx screwdriver and the 5 mm hex wrench to attach the unit to the trackway.
M6x25
M6x12
Part number (bracket):
DYS-0466-71-04-00-0
Part number:
MST-0541-10-02-00-0