Page 5 of 38
939564909 Rev B
®
Attaching Mounting Plate to Lifting Columns
Series 8 lifting columns are handed.
Secure the plastic strain relief block in
the notch provided in each lift column
before assembling mounting plate.
Locate and install each mounting plate
using 5mm (for Series 5) or 6mm (for
Series 8) hex head fasteners provided.
Do not over-tighten.
3
8mm HEX HEAD M5 x 25 BOLTS
WIRING
HARNESS,
NOTCH
MOUNTING PLATE
MOUNTING PLATE
10mm HEX HEAD M6 x 25 BOLTS
TOWARD CENTER
OF WORKSURFACE
TOWARD BACK
OF WORKSURFACE
PLASTIC STRAIN RELIEF
TOWARD CENTER
OF WORKSURFACE
STUDS ON BACK OF
LIFTING COLUMN
(TIGHTEN GENTLY WITH
3mm HEX KEY IF LOOSE)
Series 5
Series 8
STUDS ON BACK OF
LIFTING COLUMN
(TIGHTEN GENTLY WITH
3mm HEX KEY IF LOOSE)