Coordinating the Lifting Columns
Prior to initial use of the height adjustment function you must "synchronize the system".
The installers who setup the worksurface may have already done so, but it's OK to
repeat this function.
Synchronize the System
• Press the Down arrow until the worksurface comes to a stop at the lowest position.
• Release the Down arrow.
• Press and hold the down arrow for approximately 5 seconds while the table
synchronizes itself. The surface will lower itself approximately 5mm, then rise
approximately 5mm and finally settle back to its lowest position.
NOTE:
It may be necessary to repeat the synchronization process more than once.
After performing this function, the movement of all lift columns connected is
coordinated.
In the unlikely event that an error occurs, reset the control unit by pressing the Up and
Down buttons at the same time for 5 seconds. Then repeat the synchronizing sequence
as previously outlined above.
Raise or lower desk height by pressing
buttons on the console.
NOTE:
For Guidelines on Moving the Table, see page 19.
For Wiring Guide, see page 20.
Connect safety key to magnetic attachment area on
front of keypad.
Pull console forward.