background image

FitWork

 Walkstation

Series 7 AdjusTable

If you have a problem, question, or request, call
your local dealer, or Steelcase Line 1 at

888.STEELCASE

 (888.783.3522)

for immediate action by people who want to help you.
(Outside the U.S.A., Canada, Mexico, Puerto Rico, 
and the U.S. Virgin Islands, call: 1.616.247.2500)
Or visit our website: www.steelcase.com

©

 

2015 Steelcase Inc. 

Grand Rapids, MI 49501 
U.S.A.  
Printed in U.S.A.

®

Page 1 of 20

005720D Rev F

Tools required:

#2 Phillips Bit 

with Extension

7/16"

10mm 

Socket Wrench

A7TG660606H

A7TR663232H

A7TG660632H

A7TR383030H

A7TG663206H

A7TR782929H

#2 Square

Drive Bit

Summary of Contents for FitWork 7 Series

Page 1: ...t to help you Outside the U S A Canada Mexico Puerto Rico and the U S Virgin Islands call 1 616 247 2500 Or visit our website www steelcase com 2015 Steelcase Inc Grand Rapids MI 49501 U S A Printed in U S A Page 1 of 20 005720D Rev F Tools required 2 Phillips Bit with Extension 7 16 10mm Socket Wrench A7TG660606H A7TR663232H A7TG660632H A7TR383030H A7TG663206H A7TR782929H 2 Square Drive Bit ...

Page 2: ...n abrasion free surface will be necessary for table assembly Worksurface Assembly NOTCH RIGHT COLUMN LEFT COLUMN STRETCHER DOVETAIL DOVETAIL COLUMN STRETCHER TOP VIEW For each lift column fold the electrical pig tail towards the center of the surface Secure in the notch provided in each lift column 5 REAR VIEW Once each lift column has been engaged lightly tap each connection point with a rubber m...

Page 3: ...rilled holes in the top Loosely install one phillips head fastener in each of the 4 corners of the attachment plate Don t install all fasteners until the unit has been operated through one cycle Step 13 PHILLIPS HEAD SCREW 4mm HEX HEAD FASTENERS ATTACHMENT PLATE Locate and install each attachment plate using 4mm hex head fasteners provided Tighten securely 6 7 ...

Page 4: ...Page 4 of 20 005720D Rev F Remove four 4 screws on each foot Lower treadmill receiver onto legs and attach using four 4 screws on each leg SCREWS 8 9 TREADMILL RECEIVER ...

Page 5: ...the control box Secure the cord to the control box using the molded in relief as shown Do not plug into the wall outlet power source yet 8 Route lifting column cables through the molded in channels on the underside of the control box and plug into ports 1 and 2 POWER CABLE NOT YET 10 11 11 OR LIFTING COLUMN 2 CABLE LIFTING COLUMN 1 CABLE 10 12 ...

Page 6: ...hreaded studs are inserted into slot b Slide other console mounting bracket next to console making sure holes in bracket are lined up with pilot holes on worksurface c Secure bracket to worksurface using three 3 screws d Secure brackets to each side of console using two 2 nuts and two 2 flat washers e 13 SHOULDER WASHER CONSOLE SHOULDER WASHER CONSOLE MOUNTING BRACKET ASSEMBLY SCREWS SCREWS FLAT W...

Page 7: ... underside of the worksurface about 5 in front of the control box Connect the cables of each lift column Route these cables in the wire management cableway Refer to the wiring guide for more information 15 14 5 WIRE MANAGER Note stretchers and cables not shown for clarity ...

Page 8: ...a cable length into wire manager Plug the power cord into an outlet and check for binding Then lower to the bottom and unplug unit CONTROLLER CABLE FROM CONSOLE 16 LIFTING COLUMN 2 LIFTING COLUMN 1 POWER TO PIGTAILS IN COLUMNS TO PIGTAILS IN COLUMNS CONTROL BOX CONTROLLER CABLE FROM CONSOLE CONTROLLER CABLE FROM CONSOLE ...

Page 9: ...e binding The top must be lifted free rotated and set down carefully Install treadmill Align treadmill with unit as shown Make sure the two 2 treadmill feet are inserted into the two 2 holes in the treadmill receiver NOTE The holes in the treadmill receiver are for the treadmill feet not the treadmill wheels HOLE IN TREADMILL RECEIVER 18 17 TREADMILL TREADMILL FOOT ...

Page 10: ...cable as indicated b Plug the cord of the table and the treadmill into an outlet Make sure treadmill is turned on c NOTE for a b Be sure to secure signal cable to the console and treadmill with the screws integral to the cable connector This will ensure a good connection REAR OF TREADMILL 19 SIGNAL CABLE CONSOLE View from Underneath Worksurface SIGNAL CABLE CONSOLE ...

Page 11: ...5mm and finally settle back to its lowest position NOTE It may be necessary to repeat the synchronization process more than once After performing this function the movement of all lift columns connected is coordinated In the unlikely event that an error occurs reset the control unit by pressing the Up and Down buttons at the same time for 5 seconds Then repeat the synchronizing sequence as previou...

Page 12: ...ad fastener in each of the 4 corners of the attachment plate Don t install all fasteners until the unit has been operated through one cycle Step 18 1 2 Sit to Walkstation Worksurface Assembly If you want the treadmill placed on the right side use these pilot holes for attaching legs If you want the treadmill placed on the left side use these pilot holes for attaching legs Underside of Worksurface ...

Page 13: ...move four 4 screws on one foot on the side of the table where the treadmill will be installed left side installation shown Lower treadmill receiver onto leg and attach using four 4 screws SIT WALK TREADMILL RECEIVER 3 4 SCREW SCREW ...

Page 14: ...Page 14 of 20 005720D Rev F Repeat steps 12 through 15 on pages 5 6 7 Install the controller to the underside of the worksurface towards the middle of the worksurface as shown 5 6 ...

Page 15: ...f 20 005720D Rev F Install the wire keepers for the control wire Peel off paper backing and stick to worksurface Place wire into each wire keeper Repeat step 16 on page 8 CONTROL WIRE WIRE KEEPER 7 PAPER BACKING ...

Page 16: ...20D Rev F 8 Carefully turn the table over 2 person operation NOTE DO NOT use either lift column as a brace when turning the table over as this may cause binding The top must be lifted free rotated and set down carefully ...

Page 17: ... receiver NOTE The holes in the treadmill receiver are for the treadmill feet not the treadmill wheels Plug in cable from back of treadmill to back of console as shown on step 19 on page 10 Also plug cord of the table and the treadmill into an outlet make sure the treadmill is on as shown on step 19 on page 10 RECEIVER 9 10 HOLE IN TREADMILL TREADMILL FOOT TREADMILL ...

Page 18: ...5mm and finally settle back to its lowest position NOTE It may be necessary to repeat the synchronization process more than once After performing this function the movement of all lift columns connected is coordinated In the unlikely event that an error occurs reset the control unit by pressing the Up and Down buttons at the same time for 5 seconds Then repeat the synchronizing sequence as previou...

Page 19: ... position during transport and when tipped off the pallet at the new location Before in use in the location the table must again be completely leveled side to side and front to back Failure to do so may cause binding of the leg s and failure to operate properly After moving the legs must be re synchronized by holding down arrow on the controller while the legs seek to level themselves 1 2 3 4 STRE...

Page 20: ...he Control Box Follow Steps 15 through 17 beginning on page 8 to complete the wiring installation Once you have completed the wiring use the Wire Management Cableways to hold all the cables and minimize possible entanglements NOTE Cableways and vertical wire management solutions are also available Contact us for more information Wiring Guide 1 2 3 4 5 ATTACHMENT PLATE FOOT GLIDES CONTROL BOX Never...

Reviews: