Types of installation
Built-in installation
DO NOT USE THE BARBECUE IN THE TOP VERSION
WITHOUT FITTING THE FOOT FIRST.
Place the top on a flat
surface and ensure it is stable by tightening the foot adjustment
screws.
The barbecue may be installed free standing, on a
metal
shelf
or
built into a brick structure.
In any case,
the following guidelines must be followed.
Leave a gap of at least 5 cm from the side walls and any
back wall. In built-in installations the adjacent walls must
not be higher than the work surface of the barbecue. If an
additional top is installed, it must be at least 1 m higher
than the barbecue grills.
SMALLER DISTANCES THAN THOSE INDICATED MAY
CONSTITUTE A RISK FOR THE USER'S SAFETY AND
DAMAGE THE STRUCTURE OF THE BARBECUE.
This appliance must be installed by an authorised person
in accordance with this instruction manual, AS/NZS 5601.1
– Gas installations (installation and pipe sizing) and local
gas fitting regulations.
LPG: the supplied hose and regulator must be fitted to
the appliance inlet connection. Gas pressure is 2.75 kPa.
The isolating manual shut-off valve connection point
must be accessible when the appliance is installed.
The hose assembly must not be subject to strain,
abrasion, kinking or deformation and must not be in
contact with the floor or any hot or sharp surfaces.
Minimum LPG cylinder is 4.5 kg and the maximum LPG
cylinder is 9.0 kg
Natural Gas:
the supplied regulator must be fitted to
the appliance inlet connection. Gas pressure must be
adjusted to 1.0 kPa when approximately 50% of the
burners are on high flame; the appliance test point is
located on the regulator.
Suitable for connection with rigid pipe or flexible hose.
The isolating manual shut-off valve connection point
must be accessible when the appliance is installed.
Flexible hose must comply with AS/NZS 1869 Class B or
D, be of appropriate internal diameter for the total gas
consumption, be kept as short as possible
(not exceeding 1200mm), must not be in contact with
the floor or any hot or sharp surfaces. The hose
assembly must not be subject to strain, abrasion,
kinking or deformation.
If applicable, a restraining device must be fitted to