Page 15
POWER CONNECTION
Make sure your power supply matches the motor
requirements.
Connecting power wire shall be larger than 18AWG x 4C
wire. Power connections and ground must meet with
local electrical codes and safety regulations.
To prevent pull and drag of the wire when adjusting the
feeder, ensure sufficient length of cable has been
reserved when installing the power wire.
Fig. 21
WARNING
!
Fig. 21
ROLLER REPLACEMENT AND
OPERATION
1. Two types of rollers are available for selection:
Ø120 x 60mm wide (GR121)
Fig. 22
and
Ø120 x 25mm wide (RU21)
Fig. 23
.
Fig. 22 Fig. 23
2. Outer roller can be removed when operating with larger
diameter tooling.
Fig. 24
3. Inner roller could be removed from roller set to prevent
compressing workpiece to the saw blade during circular
saw operation.
Fig. 25
4. Mixed roller set up can be used for different feeding
conditions.
Fig. 24
Fig. 25
The feeder is pre-wired for 110V single phase
operation. Please refer to Wiring Diagram should
you wish to change to 220V single phase operation.
Wiring connections will need to be modified.