_________________________________________________________________________________
TOLO SAUNA
www.tolosauna.com
18
vi. Service hole
Can be used as maintenance hole or another steam outlet 1/2''.How to do maintenance, please
refer to Chapter Warranty And Services.
Steam head
Steam generator
Stean pipe
Valve
Water supply
Auto drain valve
Aromatherapy
Reservoir
Apply
silicone
here
Water magnetizer
Flexible stainless
steel hose
A
A
Steam head
300
mm
32
Figure 13
6.6. Installation of electrical circuits
Cautions
All circuits should be installed by licensed electricians and conform to local and national codes.
Power supply must be cut off before installation, maintenance and repair. Press the on/off
button on the controller can
NOT
cut off the power supply.
No additional power supply or wire is allowed to connect to the generator. Do
NOT
connect the
earth wire to the null wire.
Only the original parts and elements from our factory are allowed to be used in installation,
operation, maintenance and repair.
After the installation of the pipeline and electrical circuits, careful checking must be performed
before switch on the generator.
The generator has been carefully installed, checked and tested in factory, thus user only need to
install the power wire.
The power supply should be 215-240V or 380-415V, 50/60Hz, please refer to the nameplate of
the generator.
The selection of fuse and breaker must strictly follow the data in table 2.
Choose the suitable power wire according to table 2 and local codes.
Take off the back cover of the generator, insert the 3-core (1 live, 1 null and 1 earth) power wire
(single phase, 215-240V, 50/60Hz ) or 5-core (3 lives, 1 null and 1 earth) power wire (three
phases 380-415V, 50/60Hz) into the hole at the back of the generator case and connect to the
correct terminal. (Refer to figure12-13). After that, tightening the wire terminal to prevent
accident that wire may be fall out.