Figure 8 Steam generator 12-core cable socket corresponding functions
6.4. Installation of controller and temperature sensor
6.4.1. Cautions
The control wire and temperature wire should not be parallel to or intersect with the power
wire. The temperature sensor should NOT be installed on the side of the wall which is behind
the door.
6.4.2. Installation of controller
The controller should be installed with height of 1.2 m inside or outside the steam room but
nearby or other place where easy to operate. Firstly follow below 4 steps for install housing
box, then pull the control wire through the conduit, then connect the control wire to the
central function box. Finally the controller can be insert to the housing box on the wall (Refer
to figure 9).
Steps for install housing box: