_________________________________________________________________________________
TOLO SAUNA
www.tolosauna.com
11
Figure 7 Central function box connectors
1. APP
2. Steam room temperature sensor
3. Controller
4. Steam room humidity sensor
5. Fast steam switch
6. Fan
7. Color lights
8. Salt spray generator
9. Aroma pump
10. Descaling pump
11. Connector to the steam generator
12. Power supply 12V DC
Connect the steam generator with the central function box by using the 12-core cable we provided.
Please install the central function box near to the steam generator as close as possible.
Please note the 12-core cable can’t be extended, and only from original factory is allowable.
NOTES: (indicators explanation)
D34: Main board power supply indicator
D39: Relay contact on-off state indicator
D24: Water level detection signal indicator
D18,D19,D20: Heating indicator