WARNING

HOLD THIS FITTING SECURELY WITH A PIPE 
WRENCH WHILE MAKING A PLUMBING 
CONNECTION TO THE WATER INLET IN ORDER 
TO PREVENT INTERNAL DAMAGE TO THE WATER 
SOLENOID VALVE.

009-1054

C

US

®

LISTED 995C

STEAMBATH GENERATOR

MODEL NO.

SERIAL NO.

HEATER LOAD

VOLTS

PH

MAX AMPS

kW

CONTROL CIRCUIT

VOLTS

AMPS

50/60 HZ

SERVICE BY AUTHORIZED PERSONNEL ONLY

A PRODUCT OF STEAMIST CO., RUTHERFORD, NJ

IMPORTANT:

 

Run the Control Cable through a ¾" conduit. Remove protective cap when making the 

final connection to Control.

The Electrical Instructions must be given to the homeowner for future use.

SMC-150 or TC-150 

Control 

MUST

 be 

installed inside the 

steam room.

NOTE: Unit must be wired with 90°C wire 
in a suitable raceway, or, if local codes 
allow, provide twist lock plug on a 90°C 
wire cord from generator to a 250V 
2-pole, 3-wire grounding receptacle 
(amperage rating as required).

Control Cable

Route from 

Control to Steam 

Generator in a 

¾" conduit.

Appropriately 

fuse protected 
208/240V field 

wiring to Steam 

Generator.

Inside Installation

Control should be mounted four 

feet from the floor. Select a 

location convenient to the 

bather but not in a direct line of 

Shower or Body Sprays and not 

directly above the Steamhead.

SMC-120 or TC-125

Auxilary Outside 

Control

Electrical Installation Instructions

Figure 3 - Typical Installation

Models: SM-5, SM-7 and SM-9

06/10

Pub. No. 280-A

- 3 -

Summary of Contents for SM-5

Page 1: ...e plug and receptacle require a rating of no less than 250V and proper amperage Refer to chart on page 4 for amperage rating After the walls are complete the Steam Generator and Control can be wired 3 Steam Generator Electrical Installation WARNING All power to the Steam Generator must be turned off a Remove the two screws holding the electrical access cover and remove cover b Locate the supply li...

Page 2: ...mist com CAUTION An improperly sized Steam Generator will NOT produce the amount of steam necessary to reach selected temperature The proper voltage Steam Generator has been selected i e 208V or 240V A 208V Generator operating on 240V will damage the heating element and a 240V Generator operating on 208V will result in a 25 loss of power The Steam Generator is installed in an upright position The ...

Page 3: ... for future use SMC 150 or TC 150 Control MUST be installed inside the steam room NOTE Unit must be wired with 90 C wire in a suitable raceway or if local codes allow provide twist lock plug on a 90 C wire cord from generator to a 250V 2 pole 3 wire grounding receptacle amperage rating as required Control Cable Route from Control to Steam Generator in a conduit Appropriately fuse protected 208 240...

Page 4: ...90ºC wire guideline The NEC requires NM B type cable max current to be de rated Always follow local and national electrical codes Electrical Installation Instructions Wiring Diagram for Models SM 5 through SM 9 Models SM 5 SM 7 and SM 9 06 10 Pub No 280 A 4 Specification Chart 8 8 9 5 7 300 38 44 10 10 8 6 30 30 40 45 50 60 Model No Max Cu Ft For Area Up To KW Volt Phase Amps Wire Size 90ºC Copper...