IMPORTANT:
Run the Control Cable through a ¾" conduit. Remove protective cap when making the
final connection to Control.
The Electrical Instructions must be given to the homeowner for future use.
SMC-150 or TC-150
Control
MUST
be
installed inside the
steam room.
NOTE: Unit must be wired with 90°C wire
in a suitable raceway, or, if local codes
allow, provide twist lock plug on a 90°C
wire cord from generator to a 250V
2-pole, 3-wire grounding receptacle
(amperage rating as required).
Control Cable
Route from
Control to Steam
Generator in a
¾" conduit.
Appropriately
fuse protected
208/240V field
wiring to Steam
Generator.
Inside Installation
Control should be mounted four
feet from the floor. Select a
location convenient to the
bather but not in a direct line of
Shower or Body Sprays and not
directly above the Steamhead.
SMC-120 or TC-125
Auxilary Outside
Control
Electrical Installation Instructions
Figure 3 - Typical Installation