The proper size Steam Generator has been selected by 
using the sizing page in the “Full Line Brochure,” “Pricing 
Guide,” or “The Generator Sizing Guide” in the Residen-
tial Systems/Steambath Product Information section of 
the Steamist web site - www.steamist.com.

CAUTION: An improperly sized Steam Generator will 
NOT produce the amount of steam necessary to reach 
selected temperature.

The proper voltage Steam Generator has been selected 
(i.e., 208V or 240V). A 208V Generator operating on 
240V will damage the heating element, and a 240V 
Generator operating on 208V will result in a 25% 
loss of power.

The Steam Generator is installed in an upright position.

The proper sized 90°C wire and circuit breaker have 
been used.

The circuit breaker is NOT a GFI (Ground Fault 
Interrupter) type.

The Steam Generator is properly grounded.

The circuit breaker or disconnect switch is on.

Water supply is open to the Steam Generator.

Electrical Installation Instructions

Checklist

Models: SM-5, SM-7 and SM-9

Figure 2 - Internal Electrical Connections

06/10

Before starting, insure that the conditions of the following checklist have been met:

Pub. No. 280-A

- 2 -

Summary of Contents for SM-5

Page 1: ...e plug and receptacle require a rating of no less than 250V and proper amperage Refer to chart on page 4 for amperage rating After the walls are complete the Steam Generator and Control can be wired 3 Steam Generator Electrical Installation WARNING All power to the Steam Generator must be turned off a Remove the two screws holding the electrical access cover and remove cover b Locate the supply li...

Page 2: ...mist com CAUTION An improperly sized Steam Generator will NOT produce the amount of steam necessary to reach selected temperature The proper voltage Steam Generator has been selected i e 208V or 240V A 208V Generator operating on 240V will damage the heating element and a 240V Generator operating on 208V will result in a 25 loss of power The Steam Generator is installed in an upright position The ...

Page 3: ... for future use SMC 150 or TC 150 Control MUST be installed inside the steam room NOTE Unit must be wired with 90 C wire in a suitable raceway or if local codes allow provide twist lock plug on a 90 C wire cord from generator to a 250V 2 pole 3 wire grounding receptacle amperage rating as required Control Cable Route from Control to Steam Generator in a conduit Appropriately fuse protected 208 240...

Page 4: ...90ºC wire guideline The NEC requires NM B type cable max current to be de rated Always follow local and national electrical codes Electrical Installation Instructions Wiring Diagram for Models SM 5 through SM 9 Models SM 5 SM 7 and SM 9 06 10 Pub No 280 A 4 Specification Chart 8 8 9 5 7 300 38 44 10 10 8 6 30 30 40 45 50 60 Model No Max Cu Ft For Area Up To KW Volt Phase Amps Wire Size 90ºC Copper...