background image

All Instructions must be given to the homeowner for future use. 

 

 

 

START 

STOP 

TIME 

 

TEMP 

SENSOR HEAT 

Typical location of the DSC-425  

Control. Locate away from the  

direct line of shower spray and do  

NOT locate above steamhead. 

Steamhead Installation 

  

Steamhead should be mounted 18" 
above the finished floor or 6" above  

the rim of the tub as far from the  

bather as possible 

Installation and Operating Instructions

IMPORTANT:

 

Although the control is low voltage, power to the 

generator must be switched off before servicing electrical 
connections.

Operation: Simply press the Start/Stop keypad to begin the 
previously programmed cycle. Pressing the Start/Stop keypad a 
second time will cancel the cycle. After a cycle is started it will 
take a few minutes for the Steam Generator to heat up and begin 
producing steam.

During operation the display will flash between the remaining 
time for 15 seconds and the ambient temperature for 45 
seconds. A colon (:60) is displayed to indicate time, and no colon 
indicates temperature. The heat light will cycle on and off as the 
temperature is maintained.

Programming: There are several ways to program this control. 
Adjustments can be made while the system is active and while it 
is off. At any time the time or temperature is displayed, it can be 

Operating Instructions

Additional Features

Model: DSC-425

Figure 6

02/09

Pub. No. 120-F

- 4 - 

adjusted by simply pressing the Up or Down keypad. To 
display the time or temperature, press the Time/Temp 
keypad once or twice until it shows the setting to be 
changed. All changes made to the temperature control are 
stored in permanent memory until changed again. The 
temperature range is 50° to 130°F (10° to 55°C). The timer, 
however, has both temporary and permanent memory. Any 
adjustments made to the timer while the system is active 
will be stored in temporary memory for that cycle only. Any 
adjustments made to the timer while the system is off are 
stored in permanent memory. The temporary memory 
allows you to make adjustments to the time in accordance 
to your needs for that day without affecting the permanently 
stored time. The timer range is from :01 to :60 minutes 

     

        

Cleaning Instructions: 

Use a damp cloth and mild soap. 

Do NOT use abrasive cleaners which might scratch the 
surface or the base of the control.  

Memory:

 

The memory for both the time and temperature is 

retained even if there is a power failure.

Fahrenheit/Celsius: The temperature display may be changed 
to Fahrenheit or Celsius by simultaneously pressing and holding 
the Up and Down keypad for 5 seconds while the system is off. 
The display will show the current setting “F” or “C” and then 
alternate when the change is complete.

Error Messages: 

This control is programmed with a diagnostic 

feature to help isolate any potential problems. Error messages 

E0, E1, E2 and E3 indicate a problem internal to the 
control. If this occurs, the contorl must be replaced or 
repaired. Error messages E4, E5 and E6 indicate a 
communication problem with the Steam Generator. If this 
error occurs, check both ends of the control cable for clean, 
dry and secure connections. Dirty contacts can be cleaned 
with alcohol and a cotton swab or a toothbrush. This can 
also happen if the control is not sealed and the cable 
connections get wet. 

East Coast Office: 25 E. Union Ave., East Rutherford, NJ 07073 • Tel: 800-577-6478 • Fax: 201-933-0746
West Coast Office: 315 W. Pondera St., Suite F, Lancaster, CA 93534 • Tel: 800-355-6478 • Fax: 661-940-1617 

®

Summary of Contents for DSC-425

Page 1: ...e 1 Remove the cover from the Steambath Generator Insert multi conductor cable with strain relief provided through cabinet knockout and secure the cable to the top of the steambath generator leaving 8 of cable inside the generator Remove the protective covering labeled Remove Before Installation from the Telco Jack found on the Circuit Board Remove protective cap from plug and insert Steamist cabl...

Page 2: ...rovided It is suggested that the strain relief fitting be installed from inside the switch box so cable may be adjusted Allow approximately 10 12 of cable to extend into the box beyond the strain relief fitting Protect control cable by placing it inside the switch box during construction with the protective cap installed over the end see Figure 3 5 After the walls are finished you are now ready to...

Page 3: ...er Plate This will aid in preventing movement of this plate see Figure 5 6 Place the Cover Plate over the Center Hub This is accomplished by first hooking the top and then snapping the bottom into place 7 Adjust the Back Plate and Cover Plate to line up squarely and clean excess silicone with rubbing alcohol Installation and Operating Instructions Figure 3 Model DSC 425 02 09 Pub No 120 F 3 IMPORT...

Page 4: ...anged again The temperature range is 50 to 130 F 10 to 55 C The timer however has both temporary and permanent memory Any adjustments made to the timer while the system is active will be stored in temporary memory for that cycle only Any adjustments made to the timer while the system is off are stored in permanent memory The temporary memory allows you to make adjustments to the time in accordance...