Face Plate
Base Plate
#6-32 x 2" Long
Stainless Steel
Screw, 4 Places
Double-Sided
Adhesive Tape
2 Places
Reverse
Strain Relief
Coupler
IMPORTANT: Run the Control Cable through a ¾" Conduit.
To Generator
E
N
O
C
IL
I
S
R
A
E
L
C
.
Z
O .
L
F
2 /
1 t
e
N
0
2
5
1
3 .
o
N
m
e t I
.
A .
S .
U
N I
E
D
A
M
1/2"
Aromatherapy
Reservoir
Back Plate
O-Ring MUST
seal to inside of
the Back Plate
Cover Plate
Center Hub
3/4" NPT
(Brass Pipe)
Must use
sealant tape
Apply silicone around
the back edge of Back
Plate to seal and
prevent movement
3/8" Hex Key
Hole
Apply silicone
around the steam
pipe to form a
watertight seal
Apply a small amount
of silicone to prevent
movement
IMPORTANT:
Install top first
MUST
be vertical
After inserting the top,
snap in the bottom
Figure 5
the steamhead O-ring is fully seated into the Back Plate. If
the nipple is sticking out too far the O-ring will not make a
proper seal and the nipple must be adjusted.
5. Apply a small amount of silicone at the back center point of
the Cover Plate. This will aid in preventing movement of
this plate (see Figure 5).
6. Place the Cover Plate over the Center Hub. This is
accomplished by first hooking the top and then snapping
the bottom into place.
7. Adjust the Back Plate and Cover Plate to line up squarely,
and clean excess silicone with rubbing alcohol.
Installation and Operating Instructions
Figure 3
Model: DSC-425
02/09
Pub. No. 120-F
- 3 -
IMPORTANT: Apply Silicone around the edge of the control to
form a watertight seal to the wall (see Figure 4).
Cleaning Instructions: Use a damp cloth and mild soap. Do
NOT use abrasive cleaners which might scratch the surface or
the base of the control.
Installation Instructions for Steamhead & Center Hub
1. Make sure the 3/4" nipple protrudes beyond the tile
approximately 1/2" (see Figure 5).
2. Wrap the nipple with pipe sealant tape.
3. Put a bead of silicone around the outer edge of the Back
Plate (see Figure 5) and center the Back Plate over the
pipe in an upright position. While holding it in place screw
the Center Hub onto the nipple, using a
⅜
" Hex Key to
tighten.
4. The Center Hub MUST be aligned with the four walls in the
vertical and horizontal position (see Figure 6). Make sure
Figure 4