background image

Client

Drayton

File Name

8443 Drayton LP10RF & D3RF 06515087001 ISSE

Artworker

-

Proof Stage

03

Finished Size

A5 148x210mm

Creative Director

Mike Lane

Artwork %

100%

Modification Date

27/04/17 3:20PM

Bleed

3mm

LP10RF & D3RF

Radio frequency controlled programmable room 

thermostat with domestic hot water programmer

Part number RF561DR

Installation & User Guide

06515087001 ISSE

For GREENSTAR CDi, GREENSTAR i JUNIOR and GREENSTAR Si MODELS also

GREENSTAR i SYSTEM and GREENSTAR CDi SYSTEM MODEL(only when used with  

the optional integral diverter).

!

Spares Part number 22092

Spares Part number 22589DR

Support

401 Southway Drive

Plymouth

PL6 6QT

United Kingdom     

Technical:

 +44(0)333 7000 622            

[email protected]   

www.draytoncontrols.co.uk               

 

@DraytonHeating

  /DraytonControls

Summary of Contents for DIGISTAT+3RF

Page 1: ...oom thermostatwithdomestichotwaterprogrammer PartnumberRF561DR Installation UserGuide 06515087001ISSE ForGREENSTARCDi GREENSTARiJUNIORandGREENSTARSiMODELSalso GREENSTARiSYSTEMandGREENSTARCDiSYSTEMMODEL onlywhenusedwith theoptionalintegraldiverter SparesPartnumber22092 SparesPartnumber22589DR Support 401SouthwayDrive Plymouth PL66QT UnitedKingdom Technical 44 0 3337000622 customer care draytoncontr...

Page 2: ...rtimebegins LastSundayinMarchat 1 00amGMT Clocksareputforwardby1hour Summertimeends LastSundayinOctoberat 2 00amBST Clocksareputbackby1hour Protectyourenvironment Properbatteryrecycling Electronicdevicesandbatteries rechargeableornot shouldnotbedisposedofintoordinaryhouseholdwaste Instead theymustberecycledproperlytoprotect theenvironmentandcutdownthewasteofprecious resources Yourlocalwastemanagem...

Page 3: ...erday 25 C Batterylife withalkalinebatteries approx 2years N A Batterybackuptimeanddate 10yearsmin 10yearsmin Shortestswitchingperiod 1minute 1minute Hotwaterpre heatsettings 3ON 3OFF Centralheatingsettings 6perday EnergyClass IV 2 Acc EU811 2013 812 2013 813 2013 814 2013 PollutionClass 2 2 SoftwareClass A A Ballpressuretest 90 C 90 C Softwareversion 6712056 Max radiatedpower 7 5dBM 5 6mW Relevan...

Page 4: ...4times LrnandOFF willbedisplayed 2 Pressthe buttonsothedisplayshowsONanda flashingantennasymbol Thelearnmodeisnow readytoreceiveasignalfromthetransmitter duringthenexttwominutes 3 TaketheDigistat 3RFunitandstandnearthe boiler 4 Removethebatterycoverandfitthebatteries 5 ThesymbolsontheLP10RFwillstopflashingand thedisplaywillshow SSI AntennaandON CLOCK 6 30 10 30 OFF CLOCK 6 30 10 30 OFF 6 Press SET...

Page 5: ... strength see table below SignalStrength InstallationGuide LP10RF DIGISTAT 3RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF Digistat 2RF 2 Fixtheb...

Page 6: ...erature of s for the next day peratures small 1 in lower half of screen shows which time period is being set e g 1 1st period 2 2nd period etc Congratulations The unit is now set correctly to follow your required timings fig 3 oin Replace the spent Alkaline batteries ensuring ery cover pressing fully home To set a constant room temperature Manual mode 1 Press once the display shows temperature fla...

Page 7: ...ation for householders A programmable room thermostat is both a programmer and a room thermostat A programmer allows you to set On and Off time periods to suit your own lifestyle A room thermostat works by sensing the air temperature switching on the heating when the air temperature falls below the thermostat setting and switching it off once this set temperature has been reached So a programmable...

Page 8: ...hefollowingdefault settingspre programmedforyourconvenience Pre setProgram1 9til5 Weekday Monday Friday Asyoucansee at06 30 theheatingwillcomeon toraisethetemperatureto20 C At08 30 the temperaturesetpointisdroppedfrom20 Cdown to16 C itstaysat16 Cthroughouttheday until 16 30whenthetemperatureincreasesto21 C The temperaturethendropsdowntoanight setback temperatureof7 Cuntil06 30 whenthecycle repeats...

Page 9: ... Alkaline batteries ensuring correct orientation Replace the battery cover pressing fully home Fig 2 ge the batteries a battery icon will flash in the ring this time the Digistat 2RF IEC LR6 AA Alkaline batteries wn in the display the batteries igistat 2RF will cease to lacing the batteries Drayton RF To set a constant room temperature Manual mode 1 Press once the display shows temperature flashin...

Page 10: ...from 20ºC down to16ºC it stays at 16ºC throughout the day until 16 30 when the temperature increases to 21ºC The temperature then drops down to a night setback temperature of 7ºC until 06 30 when the cycle repeats for the next day To adjust these times and temperatures 1 With the product operating as normal in the Auto mode press twice until the display is flashing as shown The time will be flashi...

Page 11: ...cyclerepeatsthenextday Weekend Saturday Sunday Event 1 2 3 4 5 6 Time 7 00 9 00 12 00 14 00 16 30 23 00 Temp 21 0 18 0 21 0 18 0 21 0 16 0 1 2 3 4 5 6 17 30 22 30 Time Period Monday Friday 25 C 20 C 15 C 10 C 5 C Room T emp 06 00 08 30 12 00 14 00 25 C 20 C 15 C 10 C 5 C Room T emp 1 2 3 4 5 6 16 30 23 00 Time Period Saturday Sunday 07 00 09 00 12 00 14 00 Asyoucansee at7 00 theheatingwillcomeonto...

Page 12: ...mperature may be offset to bring it in line with other devices To adjust the temperature enter the user options select option 06 The temperature may be offset by 5 degrees by pressing the and keys Press to accept the desired change Option 07 How to restore the built in time temperature programs Enter user options select option 07 and use and keys to select desired option Off current programs retai...

Page 13: ...hanges Iftheengineerhassetyourprogramandtimings youdo notneedtodoanythingelse Justkeepthisguideinasafe placeforfuturereference Introduction Theprogrammerwillautomaticallyswitchyourhot wateronandoffattimesthatsuityou Thegreenlightonthefrontoftheprogrammer shows whenitison LP10RFhasa7 dayprogramallowingfor differenttimingsoneachdayoftheweek forupto3 heatingperiodseachday Iftheengineerhasn tsetyourti...

Page 14: ...HU FRI 6 30 PROG OFF HW HW ON MON TUE WED THU FRI 8 30 6 30 PROG PROG MON TUE WED THU FRI PROG MON TUE WED THU FRI PROG MON TUE WED THU FRI PROG MON TUE WED THU FRI 6 30 PROG MON TUE WED THU FRI 6 30 PROG OFF HW HW ON MON TUE WED THU FRI 8 30 6 30 PROG PROG MON TUE WED THU FRI PROG MON TUE WED THU FRI PROG MON TUE WED THU FRI PROG MON TUE WED THU FRI 6 30 PROG MON TUE WED THU FRI 6 30 PROG OFF HW ...

Page 15: ...eOFFtimeandselectthenext ONtime PROG SAT SUN PROG PROG PROG PROG OFF HW HW ON 9 00 6 30 PROG SAT SUN SAT PROG SAT SUN PROG PROG PROG PROG OFF HW HW ON 9 00 6 30 PROG SAT SUN SAT PROG SAT SUN PROG PROG PROG PROG OFF HW HW ON 9 00 6 30 PROG SAT SUN SAT Settingholidays 1 Presstheset buttonuntilSETandHDAY are displayed 2 PressOKandthedisplayshows00 3 Press or tosetthenumberofdaysyourequire thesystemto...

Page 16: ...SwillbedisplayedandONwill flash 9 Press or toswitchbetweenONorOFF Ifyou chooseONthentheclockwillautomaticallyadjust thetimeforDaylightsaving IfyouchooseOFF thenthetimewillnotchangetotakeaccountofthe DaylightSavingtimechangetwiceayear J Pressset twicetoreturntothenormaldisplay NOTE dLS DayLightSavingstime DATE DATE DATE DATE DATE MON 36 8 08 DATE DATE DATE DATE DATE MON 36 8 08 UserGuide LP10RFProg...

Reviews: