FILLING BOILER WITH WATER

1.

Place 

Portable Power Steam Cleaner

on a flat, level surface.

2.

Make sure power cord is not plugged into an electrical outlet.

3.

Cautiously unscrew Boiler Cap by rotating it in a counter-

clockwise direction, and remove from unit to expose Boiler Fill 

Hole.

4.

Boiler should always be emptied after each use.  If it was not 

emptied after the last use, empty it now.  This will make it 

easier to fill with the correct amount of water.

5.

Fill included Measuring Cup to 16 oz. (473 ml.) fill line with  

water.

NOTE: To prolong the lifetime of your

Portable Power 

Steam Cleaner

, it is highly recommended that distilled or

de-mineralized water be used in unit.

6.

Carefully pour water from Measuring Cup into Boiler through  

Boiler Fill Hole.

WARNING: Extreme caution should be used when pouring  

water into the Boiler.  Do not look directly down into Boiler

Fill Hole when filling.  Keep your free hand and any 

children or pets at a safe distance.

7.

If desired, refill Measuring Cup to 16 oz. (473 ml.) fill line with 

water, and pour second cupful into Boiler.

NOTE: Do not exceed the Boiler’s maximum capacity of 

33 oz. (976 ml.).

8. 

Replace Boiler Cap, rotating it in a clockwise direction and  

ensuring that it is screwed on tightly to prevent hot steam from 

escaping and causing injury (FIGURE 7-B).

REFILLING BOILER AFTER USE

If unit has been in use, always follow these safety precautions below before removing

Boiler Cap: 
1.

Allow unit to cool for 5-10 minutes.

2.

Press and hold Steam Trigger to release all remaining steam.

WARNING: Failure to follow these precautions may result in burns from escaping steam

when the Boiler Cap is removed.

FIGURE 7

B

A

Summary of Contents for MODEL SF-246

Page 1: ...Please read all instructions before use Mail in your warranty registration card KEEP YOUR RECEIPT FOR WARRANTY PURPOSES MODEL SF 246 Portable Power Steam Cleaner by Top Innovations ...

Page 2: ...ry and reduces smoke and other unpleasant odors making carpet and furniture seem like new again Use the Portable Power Steam Cleaner in your living room garage bedrooms automobiles bathrooms and anywhere else that you need to clean thanks to its convenient portable design And when you re finished steaming the Portable Power Steam Cleaner is easy to clean and store Top Innovations would like to inv...

Page 3: ...with adequate current capacity Use care to position extension cord where it will not be damaged or tripped over 4 Before plugging power cord into electrical outlet be sure that all electrical information on rating label agrees with your power supply 5 To reduce likelihood of circuit overload DO NOT operate another high wattage appliance on the same circuit as this unit 6 To protect against risk of...

Page 4: ...act with hot water emitting from steam vents check appliance before each use by holding Main Steam Nozzle away from body and pressing Steam Trigger Do not operate unit if steam vents are blocked 18 Burns can occur from touching hot metal parts hot water or steam Do not touch Main Steam Nozzle or attempt to connect or remove attachments while unit is in use Do not turn unit upside down it may conta...

Page 5: ...le missing parts refer to the Customer Support section on Page 14 of this manual UNIT FEATURES ACCESSORIES Boiler Cap Boiler Fill Hole Boiler internal Heating Indicator Light Strap Tabs Main Steam Nozzle Steam Trigger Steam Lock Switch Steam Hose Extension Wands 2 Utility Head Cloth Cover Shoulder Strap Jet Nozzle Nylon Brush Brass Brush Nozzle Tip Measuring Cup 1 1A 1B 2 3 4 5 5A 6 7 8 9 10 11 12...

Page 6: ...ad 8 connects to the Jet Nozzle and is designed for cleaning floors and other large surfaces The Utility Head includes three modes of operation brush squeegee and neutral flat Refer to Page 8 for details The Cloth Cover 9 attaches to the Utility Head for cleaning tile hardwood and other hard surface floors while minimizing any potential heat and moisture damage The Shoulder Strap 10 hooks onto the...

Page 7: ...t Nozzle FIGURE 1 B 3 To remove press in on yellow locking button while simultaneously pulling Jet Nozzle off of Main Steam Nozzle CONNECTING THE BRUSHES OR NOZZLE TIP 1 Align Brush or Nozzle Tip with Jet Nozzle as shown FIGURE 2 A Make sure that two side pegs on tip of Jet Nozzle align with grooves inside of Brush or Nozzle Tip 2 Slide Brush or Nozzle Tip onto Jet Nozzle then rotate clockwise whe...

Page 8: ... FIGURE 3 C NOTE Jet Nozzle will NOT lock into position and can still be freely rotated However it will not disconnect from Utility Head unless turned back a full 180º 4 Utility Head has three modes of operation depending on position of levers Forward Position FIGURE 3 D lowers brush bristles for use on carpeting or upholstery Neutral Middle Position FIGURE 3 E for use on hardwood linoleum or tile...

Page 9: ...d onto Nozzle Push Wand over button and continue to push it on unit button snaps through hole on Wand FIGURE 4 B 3 Now slide second Extension Wand onto end of the one you just connected as shown FIGURE 4 C Push on firmly until yellow locking button on first Wand snaps through hole on second Wand 4 Slide Jet Nozzle with connected Utility Head onto end of second Extension Wand as shown FIGURE 4 D Pu...

Page 10: ...hen release lock to close hook FIGURE 6 B 3 Repeat Steps 1 2 this time connecting opposite hook of Shoulder Strap to rear Strap Tab Shoulder Strap should now be securely connected to the main unit ATTACHING THE CLOTH COVER 1 Wrap Cloth Cover around bottom of Utility Head so that string ties are positioned around rear connection of Head FIGURE 5 A 2 Tie string ties together to secure Cloth Cover to...

Page 11: ... from Measuring Cup into Boiler through Boiler Fill Hole WARNING Extreme caution should be used when pouring water into the Boiler Do not look directly down into Boiler Fill Hole when filling Keep your free hand and any children or pets at a safe distance 7 If desired refill Measuring Cup to 16 oz 473 ml fill line with water and pour second cupful into Boiler NOTE Do not exceed the Boiler s maximu...

Page 12: ... surface for at least 5 seconds This will insure that you have killed germs and bacteria CAUTION Always be sure that Main Steam Nozzle and other accessories are pointed in a safe direction away from yourself other people pets and plants before pressing Steam Trigger 4 Keep Steam Trigger depressed for a continuous flow of steam You may also slide the Steam Lock Switch backward while depressing the ...

Page 13: ...stilled water will help to extend the life of your Portable Power Steam Cleaner and keep it functioning at its maximum potential If distilled water is unavailable it is recommended the following procedure be used once every 2 3 uses 1 Unplug power cord from electrical outlet 2 Allow unit to completely cool at least 30 minutes 3 Press and hold Steam Trigger to release all remaining steam 4 Remove a...

Page 14: ...sive gurgling in Steam Hose and Main Steam Nozzle water drips from Nozzle Water condensation in Steam Hose Some gurgling is a natural effect of steaming process For excessive gurgling or dripping water point Main Steam Nozzle towards ground and shake to remove excess water droplets POSSIBLE CAUSE SOLUTION Boiler has been over filled Empty some water out of Boiler so that it contains no more than 3...

Page 15: ...e Year Limited Warranty you will be advised of the cost of repair before any servicing is done You must have a Return Authorization Number before returning your product for any reason For non warranty service please enclose a check for the amount required Or you may pay by money order Visa MasterCard AmEx or Discover credit card If you need to request warranty service or have any questions about c...

Page 16: ...e topinnovations com V081022 PRINTED IN CHINA PRODUCT SERIAL NUMBER For your convenience space has been provided below for you to record the serial number of your unit located on the back or bottom of the unit for easy reference when contacting our Customer Service Department __________________ _____________________________________ ...

Reviews: