Safety Notes:  

 

1.

 

The power supply must be installed according to the local standard and with GFCI 

(Ground Fault Current Interrupter). Test the GFCI before using to confirm its security 

and validity 

2.

 

The ground for electrical appliances should be connected to fixed earth wire forever.  

3.

 

To avoid electric shock, replacing the power supply wire should be done by a 

professional electrician or distributor. Users should not change it by themselves. 

4.

 

To avoid shock, no extension power line should be used. The socket should be in the 

right position. Broken electric wire should be changed in time.  

5.

 

It is forbidden to make any change, adding, or cutting to the product. 

6.

 

It is forbidden to use the product while intoxicated.  

7.

 

Children should us the product under adult supervision. 

8.

 

Adjust the water temperature slowly from colder to warmer to avoid being scalded.  

9.

 

Stop using the product if you feel uncomfortable.  

 

 

Parameter for Steam Cabin:  

 

Rated Power: 

 

 

 

3.0KW 

Rated Voltage: 

 

 

 

Double Phase AC240V 

Rated Electric Current:   

 

16A 

Frequency:   

 

 

 

50Hz 

Power Supply: 

 

 

 

On Wall 

Rated Water Pressure:   

 

0.2 – 0.6MPa 

Water Supply: 

 

 

 

DN 15 tie-in, hot/cold water 

Water Supply Location:   

 

On Floor 

Diameter of Drainage Pipe:  

 

Φ50 (drainage pipe supplied with product) 

Length of Drainage Pipe: 

 

1000mm (the maximum length after streched) 

 

 

 

Summary of Contents for WS-112

Page 1: ...Rev 3 2012 1 P a g e WS 112 Installation Operations Manual Note You must read all installation operation instructions prior to assembly and use of this unit ...

Page 2: ...T IS INCLUDED WITH THIS UNIT IS FOR INSTALLATION INTO AN OPEN FLOOR DRAIN ONLY SUBSTITUTING THE EXISTING DRAIN SHOE FOR A DIFFERENT ONE WILL NOT VOID THE WARRANTY AS LONG AS THERE NO DAMAGE OR EVIDENCE OF MISUSE TO THE BASE Note Within the Warranty period please don t take off the decals from the computer control boxes and the steam generator without manufacturer s permission Please do not maintai...

Page 3: ...e Model System Voltage Power Frequency Length Width Height WS112 32 Steam System 220V 3KW 60 50Hz 59 Inch 32 Inch 84 5 Inch WS112 36 Steam System 200V 3KW 60 50Hz 59 Inch 36 Inch 84 5 Inch WS112 40 Steam System 200V 3KW 60 50Hz 59Inch 40 Inch 84 5 Inch ...

Page 4: ...Rev 3 2012 4 P a g e ...

Page 5: ...Rev 3 2012 5 P a g e Tools required for installation Leveler Screw driver Silicone Spanner Electric Drill Triangle Ruler Hammer ...

Page 6: ...llation The distance between Wall A and Wall B should be within 1510 to 1530mm 59 5 to 60 3 inches The distance between Wall A and Wall B bottom to 2000mm 78 75inches height should be less than 10mm 4inches 1510mm to 1530mm 59 5 to 60 3 ...

Page 7: ...Rev 3 2012 7 P a g e Door Frame Installation Drill holes on Wall A and B use the inflating nut i Note For California Get the door frame fixed to wall with tapping screws and blocks 820mm 32 3in ...

Page 8: ...Rev 3 2012 8 P a g e Installing Shower Walls Get Power supply and water supply connected Attach all the panels with taping screws ...

Page 9: ...Rev 3 2012 9 P a g e Attach All Side Panels to the Floor not with custom stone base Drill hose on the floor or optional acrylic base Attach all sides with tapping screws and blocks ...

Page 10: ...Rev 3 2012 10 P a g e Apply silicone to seal the gap between panels and floor Leave the corners without silicone ...

Page 11: ...Rev 3 2012 11 P a g e Install the front fixed glass ...

Page 12: ...Rev 3 2012 12 P a g e Install the glass door with hinges ...

Page 13: ...Rev 3 2012 13 P a g e Install the door handle adjustable handheld shower bar ...

Page 14: ...Rev 3 2012 14 P a g e Installing the ceiling Connect the power and water supply to the wooden ceiling Install the ceiling with tapping screws and down the decoration cap ...

Page 15: ...Rev 3 2012 15 P a g e Install the aluminum trim ...

Page 16: ...Rev 3 2012 16 P a g e Once all is connected place the wooden shower grid floors and benches inside the unit Please do not use the unit for at least 24hours or until the silicone is completely dried ...

Page 17: ... 1 5 to 1 7 liters of warm water should be prepared than poured into the steam generator through the rubber pipe After 8 to 12 hours connect the power and press the heating key enabling the detergent to vaporize 3 We strongly advise to use a filtration system for the steam generator unit Recommended filtration system is Whirlpool WHKF DWHV General Use and Maintenance A Drops of water will continue...

Page 18: ...right position Broken electric wire should be changed in time 5 It is forbidden to make any change adding or cutting to the product 6 It is forbidden to use the product while intoxicated 7 Children should us the product under adult supervision 8 Adjust the water temperature slowly from colder to warmer to avoid being scalded 9 Stop using the product if you feel uncomfortable Parameter for Steam Ca...

Page 19: ...Rev 3 2012 19 P a g e Electrical Diagram for Control Box ...

Page 20: ...Rev 3 2012 20 P a g e S6 Wiring Diagram ...

Page 21: ... Celsius Degree 3 Temperature 4 Temperature Indicator 5 Time Setting 6 FM Radio Frequency 7 FM Radio Volume 8 FM Radio Channel 9 Chromatherapy on off 10 Ventilator on off 11 Steam on off 12 Power on Indicator 13 FM Radio Frequency 14 Mp3 on off Control Panel for Steam Cabin ...

Page 22: ...ion for Steam Cabin 1 Steam Temperature Sensor 2 LCD Display 3 Control Panel 4 Water Diverter 5 Water Flow Adjustment 6 Water Temperature Adjustment 7 Back Massage Jet 8 Steam Outlet 9 Handheld Shower Set 10 Steam Generator Cleaning Liquid Inlet ...

Page 23: ...been reached and the figure is set as a steam setting The steam generator stops working when the temperature inside is 4 degrees higher than setting temperature The steam generator automatically starts working when the temperature is 4 degrees lower than the setting The default steam setting is 113 degrees if the user does not make any setting Steam Time Setting Hold down the Steam Time Setting bu...

Page 24: ...LCD display twinkles Celsius Fahrenheit Conversion Press and hold this button for at least 3 seconds to make a conversion between Celsius degrees and Fahrenheit degrees Pictures 7 8 Steam on off This button turns the steam on off Pushing this button makes the steam symbol on the LCD display twinkle The steam function is automatically turned off when the temperature set is 4 degrees higher than the...

Page 25: ...the volume of the FM radio It will be set as the default MP3 volume Push the MP3 button for 3 seconds to finish the setting FM Radio on off Push this button and the radio station will show on the display picture 11 The FM radio is now on The radio frequency by default is the same as the radio frequency selected last time Volume Frequency Adjust Volume Push this button when the FM radio is on pictu...

Page 26: ...e Channel Memory Push button to for more than 3 seconds the figure shows 1 and turns to original setting serial number Stop pushing this button to finish setting for one channel If the serial number is used for another channel this channel will be replaced by the new channel in memory Repeat the above steps to get the favorite channels in memory At most 8 channels can be memorized Find Channel o S...

Page 27: ...Rev 3 2012 27 P a g e ...

Page 28: ... the steam function before the steam starts to come out acid steam is detrimental to plated parts If a lot of acid steam comes out the plated parts can become cloudy after some time Do not shut off the control system The scale in the steam generator dissolves in acid liquid and the system drains the dirty water out after 60 minutes Clean the steam generator every 3 months Trouble Shooting for Stea...

Page 29: ...Rev 3 2012 29 P a g e ...

Reviews: