4.2  Cutting Preparation

   4.2.1  Tightly connect the power cable to an electrical socket outlet ( refer to the Input 

 

 

 

Voltage in section 2 Technology Parameters).

   4.2.2  Connect the air pipe to the air supply equipment and the earth cable to the 

     workpiece.
   4.2.3 Turn on the power switch, the power source lamp is lit.
   4.2.4 Turn the RUN/SET switch to SET position – the air flows, Regulate the air 

 

 

 

pressure to 3.5-6.0 bar

   4.2.5 Turn the RUN/SET switch to RUN position. Regulate the current after the flow 

     stops.
   4.2.6  Preparation is complete.

NOTE (1)  The alarm lamp is on when cutting. Switch off the torch until the alarm

 

 

sounds, then press the switch again to restart cutting.

 

(2)  During automatic gas test and examination, press on the cutting torch.

 

(3)  After long use, the surface of the electrode and nozzle will have an oxidation 

 

 

reaction. Replace the electrode and nozzle. The alarm lamp will light when 

 

 

you remove the shield cup as a safety precaution.

 

4.2  Cutting Operation

   

   

   

6   

   

                                                                              

4.2  Cutting Preparation 

1

Tightly connect the power cable to electrical socket outlet (the input voltage, refer to the  section 2 technology 

parameters) 
2

connect the air pipe to the air supply equipment, the earth cable to the workpiece 

3

turn on the power switch ,the power source lamp on. 

4

now all the preparation done . 

4.3  Cutting Operation 

 

 

 

 

Note

:(

1

The alarm lamp on when cutting, it is needed to loose the switch of the torch until the alarm release, then 

press on the switch to start cutting again. 

2

In the automatic gas test and examine, press on the cutting torch, there will no reflection. 

3

After a long usage, the surface of the electrode and nozzle will have Oxidation reaction. Please replace the 

electrode and nozzle, For The alarm lamp will on when install the shield cup, and stop working, 

   

   

   

   

   

   

Turn    on   

the    power   

source   

Loose   the   

cutting   

torch   

switch   

the   torch   

leaves   the   

workpiece,   

the   cutting   

arc   change   

into   pilot   arc   

again   

press   on   the   

cutting   

switch       
   

Ignite    the   

pilot   arc   

Post-­‐gas   for   
10s   

   

shift   to   the   

workpiece,   the   

pilot   arc   

change   into   

cutting   arc   

Arc   

extinguished   

Summary of Contents for DIGI-CUT 60-1

Page 1: ...Part No 9031H DIGI CUT 60 1 OPERATOR S MANUAL...

Page 2: ...completely before attempting to use this equipment Save this manual and keep it handy for quick reference Pay particular attention to the safety instructions provided for your protection Contact your...

Page 3: ...CONTENTS 1 SAFETY 4 2 TECHNICAL INFORMATION 6 3 INSTALLATION 8 4 OPERATION CONTROL AND CONNECTORS 9 5 MAINTENANCE 11 6 TROUBLESHOOTING 12 7 MAIN ELECTRICAL DIAGRAM 14 STEALTH DIGI CUT 60 1...

Page 4: ...ngerous to your health Use special equipment such as water or down draft cutting tables to capture fumes an Do not use the plasma torch in an area where combustible or explosive gases or materi Phosge...

Page 5: ...your skin The plasma arc process produ violet and infra red light These arc rays will damage your eyes and burn your skin if you are not To protect your eyes always wear a cutting helmet or shield Al...

Page 6: ...m transformer the main transformer and rectified by medium frequency rectifier fast recovery diode and is outputted by inductance filtering The circuit adopts current feedback control technology to in...

Page 7: ...information 2 3 Features 2 3 1 IGBT parallel balanced current technology and digital control technology 2 3 2 Wider input voltage flexibility provides peak performance power under variable conditions...

Page 8: ...the SET down position Check if there is any oil or moisture in the air 6 3 Installation 3 1Unpacking Use the packing lists to identify and account for each item 1 Inspect each item for possible shippi...

Page 9: ...no impurity and moisture in the compressed air 10 Mains cable Connect to the appropriate power supply 11 Power switch Turn on or off the power source 5 4 Operation 4 1 LayoutOfTheFrontAndRearPanel 1 p...

Page 10: ...ht when you remove the shield cup as a safety precaution 4 2 Cutting Operation 4 2 CuttingPreparation 1 Tightly connect the power cable to electrical socket outlet the input voltage refer to the secti...

Page 11: ...andle Do not attempt to over tighten the shield cup as irreparable damage to internal components may result 9 5 Maintenance 5 1Cuttinggunmaintenance Warning 1 Check the consumable parts for damage if...

Page 12: ...6 2 4 Faulty components in unit return to your distributor for repair or have a qualified technician repair using the Service Manual 6 3 No cutting output Torch is activated power source is on gas fl...

Page 13: ...n unit return to your distributor for repair or have a qualified technician repair using the Service Manual 6 7 No gas flow the power lamp is on and fan operates 6 7 1 Gas not connected or pressure to...

Page 14: ...14 STEALTH DIGI CUT 60 1 7 MAIN ELECTRICAL DIAGRAM 5 3Electricalprincipledrawing...

Page 15: ...15 STEALTH DIGI CUT 60 1...

Page 16: ...STEALTH DIGI CUT 60 1...

Reviews: