![background image](http://html1.mh-extra.com/html/stealth/9012h/9012h_operators-manual_1368270016.webp)
STEALTH DIGI-TIG 320 AC/DC PULSE
Available parameters where 2T and 4T mode have been selected:
Tpr
Gas pre-flow time
Unit
S
Setting range
0-2
Is
Starting current (only with 4T)
Unit
A
Setting range
10-320
Factory setting
Tup
Upslope time
Unit
S
Setting range
0-10
Ip
Welding current
Unit
A
10-320
Ib
Base current
Unit
A
10-320
Dcy
Ratio of pulse duration to base current duration
Unit
%
Setting range
5-95
Fp
Pulse frequency
Unit
Hz
Setting range
0.5~200
16
INSTALLATION AND ADJUSTMENT
17
Available parameters where 2T and 4T mode have been selected:
Tpr Gas pre-flow time
Unit S
Setting range 0
—
2
Is Starting current (only with 4T)
Unit A
Setting range 10
—
320 (TIG 320)
;
10
—
400(TIG 400)
Tup Upslope time
Unit S
Setting range 0
—
10
Ip Welding current
Unit A
10
—
320 (TIG-320)
;
10
—
400 (TIG-400)
;
Ib Base current
Unit A
10
—
320 (TIG-320)
;
10
—
400 (TIG-400)
;
Dcy Ratio of pulse duration to base current duration
Unit %
Setting range 5
—
95