background image

Manual

Pressure Transmitter and Reader 

of the PT-RF Series 

Summary of Contents for PT-RF

Page 1: ...Manual Pressure Transmitter and Reader of the PT RF Series...

Page 2: ...itter PT RF 9 4 1 Installing the pressure transmitters 9 5 Carrying out a measurement 10 5 1 Preparing a measurement 10 5 2 Individual measurement 12 5 3 Continuous measurement 13 6 Functions 15 6 1 S...

Page 3: ...ice and will result in immediate expiration of any warranty and guarantee claims towards the manufacturer Warning Using the selected product outside the specifications or disregarding the operating an...

Page 4: ...ecting the pressure transmitters The pressure transmitter can be damaged if the overload pressure is exceeded depending on length frequency and height of the pressure spike In case of air inclusions t...

Page 5: ...ycle any electrical appliances sold after this date free of charge Electrical appliances must therefore not be introduced into the normal waste streams Electrical appliances have to be recycled and di...

Page 6: ...PT RF V1 3 page 6 of 30 Information about battery disposal In the EU the disposal of batteries is subject to the Battery Directive 2006 66 EU in Germany to the Battery Act BattG dated 25 June 2009 an...

Page 7: ...o KG Im Ehrenfeld 4 D 58791 Werdohl Phone 49 0 2392 916 0 Operating instructions PT RF V1 3 page 7 of 30 2 Scope of Supply reading device Reader PT RF power supply unit 230 110 V 1 2 A USB 2 0 cable s...

Page 8: ...G Im Ehrenfeld 4 D 58791 Werdohl Phone 49 0 2392 916 0 Operating instructions PT RF V1 3 page 8 of 30 3 Reading device Reader PT RF micro USB connection measuring key function key on off button antenn...

Page 9: ...nection depending on the version The pressure transmitter has to be installed in line with these connections Connection using STAUFF Test SDA adaptors can be fitted for direct connection with test cou...

Page 10: ...g device will start with the start screen which displays the charging state and the available free memory Set time and date before using the reading device This cannot be carried out on the actual rea...

Page 11: ...sure transmitter as shown in the read out image below To record a measuring value the antenna has to remain within the measuring area during the measuring process PC connection function box illuminate...

Page 12: ...is stored in the memory of the reading device together with temperature ID serial number and pressure zones Conversion bar psi C F is done by the software If no connection to the pressure transmitter...

Page 13: ...ment the continuous measurement symbol will appear in the upper right corner and the number of measurements will be shown below the pressure value Measurement results are stored in the memory with a r...

Page 14: ...will be displayed on the screen The measurement data up until the error message are stored in the memory Releasing the key ends the measurement and displays the result on a screen Last measured value...

Page 15: ...warning message will be displayed In this case the reading device has to be charged To do this connect the USB charger set supplied to the device If you continue to use the reading device despite the...

Page 16: ...cted to the charger or a PC via a USB cable the LED lights up red to indicate charging of the lithium ion battery If it lights up green the storage battery is fully charged and the device can be disco...

Page 17: ...e reading device to be at the optimum distance to the pressure transmitter If the position is less than ideal this can result in a longer loading time or transmission time of the reading device This c...

Page 18: ...s easy display and processing of the measurement values as well as data export to Microsoft Excel 7 1 Installation To install the PT RF Soft software insert the data medium into your drive or download...

Page 19: ...tware can be started from the Start menu on the PC After starting the user interface appears as shown below On the left side of the interface the different functions of the software can be run on diff...

Page 20: ...a couple of seconds the Status field in the upper left corner will change from red to green and you are ready to use the Download function During the first connection it is possible that finding the...

Page 21: ...his shows the type of measurement that has been used If the measurement was a single measurement it is shown Single If the measurement was a continuous measurement it is shown Continuous and the resul...

Page 22: ...e 22 of 30 Tolerance Configurable negative tolerance of the measuring point Maximum system pressure Configurable maximum system pressure Minimum system pressure Configurable minimum system pressure Cu...

Page 23: ...n was used Save selected By pressing this button all measurements that are shown on the list are stored and saved as a PT RFs file format Save all By pressing this button all measurement are stored Th...

Page 24: ...rements that are shown on the list are saved as a csv file You can open this file with excel or any spreadsheet program for further processing When you open the measurement data in Excel it may happen...

Page 25: ...ecord Excel is necessary for this The first selected data record is output in a report Further marked measurement appear on a second page Example Standard Report Sheet Stauff provides various report t...

Page 26: ...Erase Memory By using this function the memory of the reader is emptied Restoring it again is not possible Sensor Naming When using this button a sub menu will open In this menu it is possible to att...

Page 27: ...list are three filter options can be found Serial No of sensor Time from and Time until Here the data can be filtered by the sensor serial number or the time of the measurement Reset Filter will rese...

Page 28: ...fore cleaning and disconnect it from the power supply Caution Caution Aggressive cleaning agents such as solvents petrol or similar hydrocarbons must not be used These substances could damage the hous...

Page 29: ...x 1 02 in weight 80 g 18 lbs Temperature range media temp 30 C 135 C 22 F 275 F ambient temp 30 C 85 C 22 F 185 F storage temp 50 C 100 C 58 F 212 F Response time typ 250 ms max 400 ms Long term stab...

Page 30: ...temperature in C and F display graphic LED backlit visible area 55 x 46 mm 2 17 x 1 81 in resolution 128 x 64 Pixel Storage battery lithium ion 3 7 V DC 900 mAh Operating time approx 6 h approx 1800...