background image

Operation and display elements

The Battery Charger Pb SH-3.110 is equipped with a clear operation and 
display panel. The LEDs inform you about the operating status, the charging 
status of the rechargeable battery as well as a reverse-poled rechargeable 
battery at any time. 

Description of operating mode and functions

12 V mode

The charger is suitable for charging 12 V lead batteries (please observe the 
information of the manufacturer of the battery). After the device has been 
connected, charging starts automatically. The operating indicator (1) lights up.

Even with a very low battery voltage of 1.5 V the device starts charging.  
Therefore, deep-discharged batteries can be charged as well.

The charging current is 1.5 A. The final charge voltage is 13.8 V. The charging 
status is indicated by LED (2). If the battery is full, the LED is constantly on 
and the battery charger automatically switches into float charging phase.

Note: 

The Battery Charger Pb SH-3.110 is suitable for continuous operation.

Desulphation function

As soon as the charging current drops below the maximum of 1.5 A, the 
device starts pulse operation – LED (3) starts flashing.

During charging as well as during float charging phase the device applies 
short current pulses to the battery in order to remove harmful sulphate 
layers. Thus, an already damaged battery is regenerated and its performance 
significantly increased. With new batteries, the formation of sulphate layers is 
prevented and the full performance of the battery is maintained.

Protection against short circuit and reverse polarity

The charger automatically recognises defective rechargeable batteries, a 
short circuit or a battery which has been connected with wrong polarity. In 
these cases, charging will not start. If the polarity is wrong, LED (4) lights up.

Charging the battery

 

„

First ensure that it is a 12 V lead battery. 

Rechargeable batteries with 

other voltages cannot be charged! 

 

„

Please strictly observe the information of the manufacturer of the  
rechargeable battery concerning permissible final charging voltage  
and maximum charging current.

 

„

Disconnect all consumers from the rechargeable battery.

 

„

If the rechargeable battery is built into a vehicle, switch off the ignition 
and all consumers.

 

„

First, connect the charger to the power supply (100 – 240 V AC, 50/60 Hz). 

 

„

Connect the desired connection adapter with the charging cable of  
the device.

 

„

Connect the charger to the rechargeable battery observing correct  
polarity. A polarity-reversed connection cable is indicated by LED (4).

 

„

After charging, disconnect the battery charger from the power supply.

 

„

Then remove the terminal from the minus pole of the rechargeable  
battery and then from the positive pole.

 

Operating indicator  

 

(on, when voltage is applied)

 

Charging status indicator 

 

(on, at full battery)

 

Pulse operation (LED flashes)

 

Fault indicator (on, at reverse  

 

polarity connection)

1

2

3
4

1 2 3 4

GB

i

Please strictly observe all information and safety instructions of 
the vehicle and on how the vehicle battery needs to be charged. 
Modern vehicles are equipped with sensitive electronic compo-
nents and control units, which will be damaged when handled 
improperly!

/ 11

More information at 

 

www.ivt-hirschau.de

/ 10

3 years

 

manufacturer’s warranty. Rechargeable batteries and batteries excluded. 

Summary of Contents for Pb SH-3.110

Page 1: ...Bedienungsanleitung Batterie Ladeger t Pb SH 3 110 Instruction Manual Battery Charger Pb SH 3 110 DE GB Article no 331100 3...

Page 2: ...entsorgen Sie es umweltgerecht Betrieb Der Betrieb unter widrigen Umgebungsbedingungen ist unter allen Umst nden zu vermeiden Widrige Umgebungsbedingungen sind Umgebungstemperaturen ber 40 C brennbar...

Page 3: ...es Akkus erhalten Kurzschluss und Verpolungsschutz Defekte kurzgeschlossene bzw verpolt angeschlossene Akkus werden vom Ladeger t automatisch erkannt In diesen F llen wird der Ladevorgang nicht gestar...

Page 4: ...sabfall entsorgt werden sondern muss an einem Sammelpunkt f r das Recycling von elektrischen und elektronischen Ger ten abgegeben werden Das Symbol auf dem Produkt der Gebrauchsanleitung oder der Verp...

Page 5: ...voided under all circumstances Unfavourable environmental conditions include ambient temperatures above 40 C flammable gases solvents vapours dust and relative humidity in excess of 80 The charger may...

Page 6: ...rcuit and reverse polarity The charger automatically recognises defective rechargeable batteries a short circuit or a battery which has been connected with wrong polarity In these cases charging will...

Page 7: ...9622 7199120 info ivt hirschau de www ivt hirschau de Environmental protection note At the end of its useful life this product may not be disposed of together with normal household waste but has to b...

Page 8: ...terkabel k nnen auch separat bestellt werden The adapter cables may also be ordered separately Adapterkabel mit Batterieklemmen Art Nr 911000 K Adapter cable with battery clamps Order no 911000 K Adap...

Page 9: ...taudte Hirsch Designed in Germany Powered by IVT IVT Innovative Versorgungstechnik GmbH Dienhof 14 D 92242 Hirschau fon 49 0 9622 71991 0 fax 49 0 9622 71991 20 info ivt hirschau de www ivt hirschau d...

Reviews: