Servicing should only be performed by a Qualified Service Technician
LOWER TEMPERATURE PROBE CONTINUITY CHECK
OHMS RESISTANCE TABLE
° F
OHMS
70°
11,884
120°
3,759
140°
2, 488
180°
1, 169
Lower Temperature Probe continuity check
Red wire to red wire – Turn supply power "Off" for this test.
IF.........
THEN............
Test indicates
no continuity
.
Replace probe.
Continuity
is indicated.
Probe should be okay (also verify Ohms resistance for water
temperature). (Reading will be approximate.)
CONDITIONS:
• Main burner ignited.
• Stored water is below temperature setting more than 5° F (Tank Average).
• Power Off.
• Plug disconnected from digital thermostat receptacle E4.