9
Servicing should only be performed by a Qualified Service Technician
BLOWER AND BURNER ASSEMBLY
BURNER REPLACEMENT:
1. Turn off the gas supply and electricity to the water heater.
2. Disconnect the spark ignition cable and ground wire plus the flame sensor wire at their connection points
on the flange plate.
3. Disconnect the vacuum hose at the air intake connection if necessary. Disconnect the pressure hose at
blower outlet connection.
4. Disconnect the gas valve from the blower at the gas valve flange by unscrewing the 4 retaining screws.
Keep the o-ring that is located in the flange groove. This o-ring seals the flange to the gas valve.
5. Remove the 4 fasteners joining the blower flange to the adapter tube. Save the silicone gasket between
the blower flange and the adapter tube.
6. Move the blower aside and support it so that it will not hang from the power connection wires.
Burner
Skirt Ring
Flange Gasket
Flange
Plate
Silicone
Gasket
Blower
Spark Igniter
Flame
Sensor
Burner
Gasket
Brass nuts/
Lockwashers (4)
Fasteners (4)
Gas Control
Valve
Adapter
Tube
Blower
Flange
Brass Locknuts (3)
Fasteners (4)
Gas Orifice
Gas Valve
Flange
Summary of Contents for SBL85275NE