Remote System Monitor
4-17
Chapter 4 - Maintenance and Troubleshooting
STARPLUS STSe - Installation Manual
August 2005
4. Press <Enter> to enable the trace. A screen similar to the following displays:
Figure 4-7: Enable Event Trace
5. To disable or turn off a particular trace mode,
do
not enter
a specific board, CO Line or
Station Number (e.g.,
t<space>s<return>
to disable station event trace).
To have event traces displayed on the screen, exit the MONitor mode by typing
X
at the
mon> prompt.
After exiting the event(s), the trace begins as shown in
.
Modify Memory Command
The Modify Memory command is for “
engineering use
only”.
Unless instructed by personnel at Vodavi Technical Support, do not leave the trace mode
enabled for extended time periods. The system dumps the requested event(s) trace which
may use up paper or fill memory buffers on the collecting device. It is recommended that
the trace events be disabled (turned off) for all event(s) traces before leaving the system site
unless otherwise instructed by Technical Support.
Using this command can alter or damage the STSe System operating database which can result
in system malfunction. If this occurs, power the system down and re-initialize the database, then
completely reprogram the customer programming data.
Summary of Contents for STSe Key System
Page 1: ...August 2005 Issue 1 0 STARPLUS STSe Key Systems Installation Manual TM...
Page 4: ......
Page 10: ...vi Figures STARPLUS STSe Installation Manual August 2005...
Page 12: ...viii Tables STARPLUS STSe Installation Manual August 2005...
Page 14: ...N O T E S...
Page 22: ...N O T E S...
Page 30: ...N O T E S...
Page 68: ...3 40 Door Box Chapter 3 Installation STARPLUS STSe Installation Manual August 2005...
Page 70: ...N O T E S...
Page 94: ...iv Index STARPLUS STSe Installation Manual August 2005...