17/12/2018
15
AVB Connections
CDE 240 AVB Connections
•
Part #:
CDE 240 AVB Connections
•
Date:
16/02/2020
•
Version:
1-A
The CDe180 are supplied with Atmospheric Vacuum Breaker as the source of backflow
prevention to prevent contamination of supply water as required. These AVBs and associated
systems within the CDe180 have been tested and confirmed as compliant with latest WMTS
101:2016 – Appliances (low hazard rating).
No additional backflow prevention devices are required to be installed with Starline
dishwashers.
Purpose of each AVB
AVB 1
Water Source: Hot Water Supply.
Water Output: Eco Rinse Tank.
AVB 2:
Water Source: Hot Water Supply.
Water Output: Wash Tank.
AVB 3:
Water Source: Cold Water Supply.
Water Output: Condenser Unit.
AVB 4:
Water Source: Condenser Unit.
Water Output: Rinse Tank.
Starline CDe180 Service Manual