26
Specific Gravity Check
Measure At The Second Cell For Battery Plus (+) Terminal.
Specific Gravity: 1.260
Measure At Cells. Use the Middle Cell as a Pilot Check Cell
for Specific Gravity Index at the Second Month, Check all
Cells at 6 Months and Use the Worst One for the Pilot Cell
Thereafter. Should Be Less Than 0.05± Deviation Between
Them.
Specific Gravity 1.280
Lower Limit Of Specific Gravity
1.230 (20ºc).
Remove Battery and Recharge if Below This Level.
1.250 (20ºc). Remove Battery And Recharge If Below This
Level.
Charging
Do Not Perform Quick Change. Measure Specific Gravity 01
Each Cell After Charging
Measure Specific Gravity Of Each Cell After Charging.
Measure the Specific Gravity of Each
Cell after Charging
Convert the Specific Gravity Of Electrolyte Into What It Would Be at a Fluid Temperature of 20ºc.
S20 = St +0.0007 (t-20)
S20:
Specific Gravity at 20ºc
St:
Actual Specific Gravity Measured
t:
Temperature of Electrolyte When Measured
RUST PROOFING
The engine compartment chassis and undersides should be cleaned, touched up and rust removed.
A rust preventative should be applied to long-term storage trucks.