background image

-8- 

Alternate Mounting 

 

If you are not using the visor clip installation described on the previous page, 
continue below. 

Because  of  the  wide  variety  of  mounting  applications,  Star 
Headlight  &  Lantern  Co.,  Inc.  assumes  no  responsibility  for 
the secure mounting of this light.  It is the responsibility of the 
installer  and/or  owner  to  ensure  the  lightbar  is  mounted 
securely.  Check your light every time you enter the vehicle to 
ensure that it is mounted securely.   

1. 

Some vehicles may not have visor clips 
appropriate for the previously described 
installation

, or may completely lack any visor clips.  

An alternate mounting screw hole is provided in the 
bracket for these situations.  This hole can be used 
with an appropriate user supplied screw or other 
suitable fastener. 

2.  If you are using the alternate mounting screw hole, you will need to locate the roof 

brace under the headliner of the vehicle. 

 
3.  Once you have located the roof brace, pick an area to mount the brackets (one on 

each side) that is a minimum of 3” from the center of your window and a maximum 
of 8”. 

 
4.  You must then determine an appropriate size screw to penetrate the headliner and 

securely mount the brackets to the roof brace.  When selecting a screw, take care to 
ensure that it is capable of supporting the weight of the light and it will not penetrate 
the roof of the vehicle. 

 
5.  Carefully drill any necessary pilot holes in your roof brace.  

CAUTION: Take care to 

ensure when selecting a screw and drilling the hole that it is capable of 
supporting the weight of the light and that it does not penetrate the roof of the 
vehicle.

 

 
6.  Install the screws through each bracket. 
 
7.  If necessary, adjust your light as described in Step 10 on page 6. 

CAUTION!!!    Once  the  light  is  secured,  route  your  cord  such  that  it 
does not interfere with the vision of the driver or the operation of the 
steering wheel, gear shifter, and/or any airbags.

 

Alternate

Mounting

Hole

Mounting (CONT'D) 

Summary of Contents for The Starburst ULB42-DLP

Page 1: ...st Phantom Starburst Phantom IMPORTANT Please read all of the following instructions before installing your new warning light Undercover Interior LED Lightbar With Generation 4 LED Takedown and Direct...

Page 2: ...1...

Page 3: ...g and or wiring may be necessary and are the sole responsibility of the installer Star Headlight Lantern Co Inc assumes no responsibility for the integrity of the installation for this or any of its p...

Page 4: ...n described Some applications may require you to design your own custom brackets The installer assumes all responsibility for the integrity of the installation It is the sole responsibility of the own...

Page 5: ...DESCRIPTION 1 P30150 220LP LEFT ATTACHING BRACKET 1 P30150 220RP RIGHT ATTACHING BRACKET 2 P30150 79P FORKED L BRACKET Style 1 2 P30150 189P FORKED L BRACKET Style 2 2 P30054 27 10 32 x 1 2 CARRIAGE B...

Page 6: ...center of the light 3 Remove two of the 8 x 1 2 self tapping Phillips pan head screws and use them to install the left attaching bracket on the light CAUTION Take extreme caution not to over tighten t...

Page 7: ...isor clips enough that one of the forked brackets can easily slide under each of them 9 Slide one forked bracket under each visor clip and tighten the clip such that it securely holds each bracket in...

Page 8: ...ght 13 Tighten the Baffle Adjusting Screws to secure the baffle in place CAUTION Take extreme caution not to over tighten the screws Over tightening of the screws can strip the holes 14 Push the light...

Page 9: ...the headliner of the vehicle 3 Once you have located the roof brace pick an area to mount the brackets one on each side that is a minimum of 3 from the center of your window and a maximum of 8 4 You m...

Page 10: ...Warning Lights Pursuit Lights Flashing DLP Takedown Lights Steady Burn DLP Orange w Red Flashing Warning Lights DLP Lights User Supplied Switches Warning Lights 10 AMP FUSE Wire Function Bare Ground B...

Page 11: ...mmend that the red wire be routed through an ignition switched power source Orange w Red Switched 12 VDC WARNING When 12VDC is applied to the Orange w Red wire the Warning LEDs will activate displayin...

Page 12: ...rning LEDs will flash according to the pattern you have selected See Pattern Select Burst Mode Button section on next page All LED Steady Burn Mode Green w Red The Warning LEDs will not flash but inst...

Page 13: ...w Red wire activated If the Star Phantom is in the Steady Burn Mode the Pattern Select Burst Mode will burst your LEDs into a super bright high power mode takedowns This mode will activate for approxi...

Page 14: ...lash Alt Flicker 29 Alt Pre Pops Alt Flicker Superfast Warn 30 Delta Omega All Double All Flicker 31 One Output Steady Other Output Singleflash 32 One Output Steady Other Output Short Long 33 Warn Med...

Page 15: ...ot apply to any light which has been altered such that in the manufacturer s judgment the performance or reliability has been affected or if any damage has resulted from abnormal use or service There...

Page 16: ......

Reviews: