ELECTRICAL CONNECTION
Before making any electrical connections to this unit, check that the power supply is adequate
for the voltage, amperage, and phase requirements stated on the rating plate. A wiring diagram
is included herewith.
ENSURE THAT BOTH THE CIRCUIT BREAKER AND THE POWER (ON/OFF) SWITCH
IS IN THE OFF POSITION BEFORE PROCEEDING.
BE CERTIAN THAT ALL PACKING MATERIAL HAS BEEN REMOVED FROM INSIDE
THE OVEN'S CHAMBER.
When installed, this appliance must be electrically grounded and its installation must comply with
the National Electric Code, ANSI-NFPA 70, latest version, manufacturer's installation instructions,
and applicable local municipal building codes. In Canada, all electrical connections are to be in
accordance with CSA C22.1 - Canadian Electrical Code Part 1 and/or local codes.
This device is equipped with a 3-prong (grounded) plug for your protection against shock
hazard and should be plugged directly into a properly grounded three prong receptacle.
DO NOT cut or remove the grounded prong from this plug.
EQUIPOTENTIAL GROUNDING - CE ONLY
On CE units, connect an equipotental ground wire to the ground lug shown in the
fi
gure below.
The equipotential ground connection must meet current IEC/CEE and local code requirements.
The ground lug is found on the rear side of the control box, below the equipotential ground
symbol.
On certain CE/UK models install the IEC plug using the cord holder provided.
UTILITY INSTALLATION
WARNING
Equipotential
Ground Lug
Cord Holder
IEC Plug
IL1242
Symbol
IEC/CEE Equipotential Ground Connection
WARNING
CAUTION