background image

8

E

Turning Off the Tool

The tool can be turned off in either of these ways: 

•  Press and hold 

 for several seconds (until the 

display window clears).

•  If you do not use the tool for 90 seconds, it will 

automatically turn off.

Warranty

STANLEY warrants this product for a period of (2) years 

against deficiencies in material and workmanship. This 

LIMITED WARRANTY does not cover products that are 

improperly used, abused, altered, or repaired. Please call 

866-786-5924 for more information or return instructions. 

Unless otherwise noted, STANLEY will repair without cost, any 

STANLEY product found to be defective, including parts and 

labor charges, or at STANLEY’s option, will replace such tools 

or refund the purchase price, less the amount for depreciation, 

in exchange for the defective tool. THIS LIMITED WARRANTY 

EXCLUDES ALL INCIDENTAL OR CONSEQUENTIAL 

DAMAGES. Some states do not allow the exclusion or 

limitation of incidental or consequential damages, so these 

limitations may not apply to you. This TWO YEAR LIMITED 

WARRANTY gives you specific legal rights that may vary from 

state to state. In addition to the warranty, STANLEY Lasers 

are covered by: 30-Day Money Back Guarantee. If you are not 

completely satisfied with the performance of your STANLEY 

Laser for any reason, you can return it within 30 days from the 

date of purchase with a receipt for a full refund.
IMPORTANT NOTE: The customer is responsible for the 

correct use and care of the instrument. Moreover, the 

customer is completely responsible for periodically checking 

the accuracy of the laser unit, and therefore for the calibration 

of the instrument.
Calibration and care are not covered by warranty.

Summary of Contents for TLM99

Page 1: ...E NL GR PT FIN HU BG LV ES DK CZ E NO SK RO F SE RU PT PL SI EE TLM99 TLM99s TLM99si User Manual Please read these instructions before operating the product www StanleyTools com DOC100270398...

Page 2: ...C 1 2 E 2 Figures A 4 STHT77509 6 21ft 6 17ft 1 2 6 17ft 4 3 6 21ft B 1 2 5 2 D AAA 6 1 3 7 5 6...

Page 3: ...2 1 3 F G H...

Page 4: ...including interference that may cause undesired operation FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC r...

Page 5: ...ery door into the notches in the battery compartment Figure D 4 5 Push the battery door down until it snaps in place Figure D 5 When the tool is ON the battery level appears in the display window Figu...

Page 6: ...On the display window the tool icon will change from to Figure E 5 3 Click twice to show on the display window Figure E 4 4 Measure the width Point the top of the tool at one side of the target room...

Page 7: ...Continuous Measure mode you can change the unit of measure from decimal ft 6 21 ft to fractional ft 6 02 9 16 fractional ft to meters 1 894 m meters to inches 74 9 16 in or inches to decimal ft On th...

Page 8: ...or depreciation in exchange for the defective tool THIS LIMITED WARRANTY EXCLUDES ALL INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow the exclusion or limitation of incidental or conseque...

Page 9: ...target area 202 Laser Beam Interrupted Remove the obstacle and repeat the measurement 203 Insufficient Power Replace the batteries 301 Temperature Too High Allow the device to cool down to a temperat...

Page 10: ...x 1 02in 120 x 48 5 x 26mm Weight with Batteries 3 21oz 100g Storage Temperature Range 14 F 140 F 10 C 60 C Operating Temperature Range 32 F 104 F 0 C 40 C Measuring Accuracy depends on the current c...

Page 11: ...n L ser Clase 2 en conformidad con la norma IEC 60825 1 y cumple las normas 21 CFR 1040 10 y 1040 11 excepto en las desviaciones en conformidad con lo establecido en Laser Notice No 50 del 24 de junio...

Page 12: ...raci n no deseada del dispositivo De conformidad con las disposiciones del Ministerio de la Industria de Canad el o los radiotransmisores de este dispositivo s lo pueden funcionar usando una antena de...

Page 13: ...perior de la herramienta Figura A 1 hacia la pared o hacia el objeto cuya distancia desee medir Figura F 3 Oprima y mantenga oprimido durante 2 segundos para encender el modo Medici n continua 4 En la...

Page 14: ...medici n de ancho en la parte superior de la ventana de la pantalla 5 Medici n de longitud Coloque la herramienta en un extremo del objetivo y apunte el punto del l ser a trav s de la longitud La figu...

Page 15: ...E 3 Cambio de la unidad de medici n Despu s de tomar la medici n actual el dispositivo no est en modo Medici n continua puede cambiar la unidad de medida de pies decimales 6 21 pies a fracciones de p...

Page 16: ...a o a opci n de STANLEY reemplazar tales herramientas o reembolsar el precio de compra menos la cantidad por depreciaci n por intercambio de la herramienta defectuosa ESTA GARANT A LIMITADA EXCLUYE TO...

Page 17: ...e fondo en la zona del objetivo 202 Rayo l ser interrumpido Elimine el obst culo y repita la medici n 203 Potencia insuficiente Cambie las bater as 301 Temperatura demasiado alta Deje que la herramien...

Page 18: ...x 48 5 x 26 mm Peso con bater as 3 21oz 100g Rango de temperatura de almacenamiento 14 F 140 F 10 C 60 C Rango de temperatura de operaci n 32 F 104 F 0 C 40 C La precisi n de la medici n depende de la...

Page 19: ...eau laser mis est de classe 2 selon la norme IEC 60825 1 et il est conforme la norme 21 CFR 1040 10 et 1040 11 except les carts conform ment l avis sur le laser n 50 du 24 juin 2007 AVERTISSEMENT Lors...

Page 20: ...fonctionnement ind sirable de l appareil Conform ment la r glementation d Innovation Sciences et D veloppement conomique Canada le transmetteur radio de cet appareil peut seulement fonctionner l aide...

Page 21: ...gure A no 2 vous pouvez voir la distance actuelle Figure E no 3 qui ne cesse de changer mesure que vous d placez l outil 5 Pour prendre la mesure entre le bas de l outil et le mur ou l objet et quitte...

Page 22: ...i me ligne de la fen tre d affichage 7 Vous pouvez voir la mesure du volume au bas de la fen tre d affichage Figure E no 3 Ajouter des mesures Vous pouvez ajouter deux mesures afin d obtenir la mesure...

Page 23: ...onnect sur votre t l phone portable ou votre tablette 2 l aide de l application STANLEY Smart Connect capturez la pi ce ou l espace dont vous souhaitez enregistrer les mesures et tablissez votre plan...

Page 24: ...ne permettent pas l exclusion ou la limitation de dommages accessoires ou indirects alors cette exclusion peut ne pas s appliquer vous Cette GARANTIE LIMIT E DE DEUX ANS vous donne des droits l gaux...

Page 25: ...ne cible 202 Interruption du faisceau laser Retirez l obstacle et r p tez la prise de mesure 203 Puissance insuffisante Remplacez les piles 301 Temp rature trop lev e Laissez l appareil refroidir une...

Page 26: ...26 mm Poids avec piles 3 21 oz 100g Plage de temp ratures de stockage 14 F 140 F 10 C 60 C Plage de temp ratures de fonctionnement 32 F 104 F 0 C 40 C La pr cision de la prise de mesure d pend des con...

Page 27: ...de acordo com a IEC 60825 1 e est em conformidade com 21 CFR 1040 10 e 1040 11 exceto os desvios indicados no aviso relativo ao laser n 50 de 24 de junho de 2007 AVISO Quando a ferramenta laser estiv...

Page 28: ...er interfer ncias incluindo interfer ncias que possam causar um funcionamento indesejado do dispositivo De acordo com os regulamentos da Industry Canada o s radiotransmissor es neste dispositivo s pod...

Page 29: ...ecisa medir Figura F 3 Aperte e mantenha pressionado durante 2 segundos para ativar o modo Medi o Cont nua 4 Na parte inferior do display Figura A n 2 verifique a medi o de corrente Figura E n 3 que f...

Page 30: ...a linha do display 6 Me a a altura Posicione a ferramenta numa extremidade do alvo e aponte o ponto do laser ao longo da altura A Figura H n 3 mostra onde posicionar a ferramenta se estiver medindo a...

Page 31: ...2 3 segundos Como usar a TLM99s TLM99si com Se voc tiver uma TLM99s ou TLM99si poder utilizar a op o Bluetooth para sincronizar o aplicativo STANLEY Smart Connect ao seu celular ou tablet e em seguid...

Page 32: ...ENTES OU RESULTANTES DE INCIDENTES Alguns estados n o permitem a exclus o ou a limita o de danos por acidentes ou resultantes de incidentes Assim essas limita es podem n o ser aplic veis no seu caso E...

Page 33: ...obst culo e repita a medi o 203 Energia insuficiente Substitua as baterias 301 Temperatura excessivamente alta Deixe o dispositivo esfriar at atingir uma temperatura de acordo com a Faixa de temperatu...

Page 34: ...72 x 1 91 x 1 02 pol Peso com baterias 3 21oz 100 g Faixa de Temperatura de Armazenamento 10 C 60 C 14 F 140 F Faixa de Temperatura Operacional 0 C 40 C 32 F 104 F A precis o de medi o depende das co...

Page 35: ...Notes...

Page 36: ...2017 Stanley Tools 701 E Joppa Road Towson Maryland 21286 U S Canada Only Made in China 097391 Rev B August 2017...

Reviews: