Stanley OISIN MK II Installation And Operation Instructions Manual Download Page 4

Fig.4

7.

To turn off the main burner, turn the con-
trol knob in a clockwise direction to low 
flame.  (see fig. 4)

Fig. 5

8.

While pressing the control knob  continue 
to turn in a clockwise direction until it 
stops.  The stove is now off.  (see figs. 
5&6)

Fig. 6

NOTE:

During the first light-up period an odour

will arise from the stove, this is due to the materi-
als in the stove drying and curing.  It is advisable
to open a door or window to give extra ventilation
to the room until the odour has gone.

WHAT TO DO IF YOU SMELL GAS 

A.

Turn off the gas mains.

B.

Do not try to light any appliance.

C.

Do not touch any electrical switch.

D.

Open windows.

E.

Do not use any phone in the building.

F.

Immediately call your gas engineer from 
a neighbours phone.

G.

If you cannot reach your gas supplier, 
call the Fire Department.

VENT SAFETY SHUT OFF SWITCH

The vent safety shut off switch location is
designed to shut down the stove when exposed to
excessive temperatures due to severe down
draughts, blocked flues or negative pressure due
to a fresh air shortage.  It must not be disconnect-
ed or isolated in any way.

WARNING:

Not to be isolated or adjusted.

Parts to be replaced with identical and/or equiva-
lent original parts

.

What to do if the vent safety shut off switch
continually goes off:

A:

Wait for 4 minutes after shut down.

B:

Refer to these lighting instructions for 
lighting procedures.

C:

If stove fails to light repeat the above 
procedures.

D:

If stove fails to light after three attempts 
contact your local Stanley Dealer.

Low Flame Setting

3

Summary of Contents for OISIN MK II

Page 1: ...stalled by a suitably qualified and competent person This appliance is hot while in operation and retains its heat for a long period of time after use Children aged or infirm persons should be supervi...

Page 2: ...4 Use of Existing Chimney s and Flues 7 15 Factory Made Insulated Chimneys 8 16 Ventilation Combustion Air Requirements 8 17 Gas Pipes Fittings 8 18 Meters 8 19 Pipe Size 8 20 Connection to Gas Supply...

Page 3: ...stove 7 Tools must not be used to turn or operate the valve control knob 8 Use only in a sufficiently ventilated space 9 This appliance must be installed in accor dance with the rules in force 10 Rea...

Page 4: ...building F Immediately call your gas engineer from a neighbours phone G If you cannot reach your gas supplier call the Fire Department VENT SAFETY SHUT OFF SWITCH The vent safety shut off switch loca...

Page 5: ...burners and circulating air passageways of the room heater are kept clean NOTE Before installation check that the local distribution conditions nature of gas and pres sure and adjustment of the applia...

Page 6: ...ar flue outlet The stove has a rear flue outlet configuration factory fitted It may be changed to a top flue outlet by simply switching the blanking cap and flue collar as shown in Fig 8 9 Fig 7 Fig 8...

Page 7: ...ion See Fig 12 Fig 15 When installing the stove against a non combustible wall leave a 2 space between the back of the stove and the wall for air circulation See Fig 15 HEARTH FITTING This stove MUST...

Page 8: ...ng to B S 4543 a galvanised finish is not suit able Clay flue linings conforming to I S 51 B S EN 1457 1999 Pre cast concrete chimney blocks incor porated into the building structure It is particularl...

Page 9: ...there is another combustion appliance fitted in the same or adjacent room it will be necessary to refer to the rules in force to calculate the additional air supply If there is an air extraction fan f...

Page 10: ...warranty Fig 21 WARNING To avoid pipe sealing compounds from entering into the gas train do not apply seal ing compound to the first two threads at the tip of the gas connection Fig 22 Fig 23 NOTE Cl...

Page 11: ...5 4 Place 4 medium coals on the front of the matrix with their corners touching and also one corner of each coal resting on a spar see Fig 26 Fig 26 6 Place 3 small coals on 3 of the medium coals leav...

Page 12: ...il the odour has gone BURNER LIGHTING 1 With the pilot flame firmly established turn the control knob anti clockwise to the high position When the main burner is lighting adjust control knob clockwise...

Page 13: ...switch located at the back of the stove See Fig 33 6 Under the two M6 wing nuts located on the under side of the stove on the right and on the left See Fig 33 7 Carefully lift up the burner assembly s...

Page 14: ...y damp cloth followed by a polish with a clean dry duster 2 For stubborn deposits a soap impregnated pad can be carefully used on the vitreous enamel 3 Use only products recommended by the Vitreous En...

Page 15: ...s Call your qualified service technician Incorrect inlet pressure Call your qualified service technician Blocked orifice Call your qualified service technician Faulty control valve Call your qualified...

Page 16: ...pable of producing a continuous draught of between 0 06 w g during normal operation Location 1 Clearance to combustible materials must be adhered to as described in the Clearance to Combustibles secti...

Reviews: