![Stanley OISIN MK II Installation And Operation Instructions Manual Download Page 4](http://html1.mh-extra.com/html/stanley/oisin-mk-ii/oisin-mk-ii_installation-and-operation-instructions-manual_1361095004.webp)
Fig.4
7.
To turn off the main burner, turn the con-
trol knob in a clockwise direction to low
flame. (see fig. 4)
Fig. 5
8.
While pressing the control knob continue
to turn in a clockwise direction until it
stops. The stove is now off. (see figs.
5&6)
Fig. 6
NOTE:
During the first light-up period an odour
will arise from the stove, this is due to the materi-
als in the stove drying and curing. It is advisable
to open a door or window to give extra ventilation
to the room until the odour has gone.
WHAT TO DO IF YOU SMELL GAS
A.
Turn off the gas mains.
B.
Do not try to light any appliance.
C.
Do not touch any electrical switch.
D.
Open windows.
E.
Do not use any phone in the building.
F.
Immediately call your gas engineer from
a neighbours phone.
G.
If you cannot reach your gas supplier,
call the Fire Department.
VENT SAFETY SHUT OFF SWITCH
The vent safety shut off switch location is
designed to shut down the stove when exposed to
excessive temperatures due to severe down
draughts, blocked flues or negative pressure due
to a fresh air shortage. It must not be disconnect-
ed or isolated in any way.
WARNING:
Not to be isolated or adjusted.
Parts to be replaced with identical and/or equiva-
lent original parts
.
What to do if the vent safety shut off switch
continually goes off:
A:
Wait for 4 minutes after shut down.
B:
Refer to these lighting instructions for
lighting procedures.
C:
If stove fails to light repeat the above
procedures.
D:
If stove fails to light after three attempts
contact your local Stanley Dealer.
Low Flame Setting
3