MRP Mobile Rotating Pulverizer Operation & Maintenance Manual | 15
MAINTENANCE
EVERY 8 HOURS
Lubrication
_______
Lubricate as shown in “Lubrication” on page 17.
_______
Inspect the grease fittings and replace if damaged.
Inspect Hardware
_______
Inspect the hardware on the attachment. Ensure they are properly torqued and are not damaged (See “Inspect /
_______
Inspect the rotation bolts. Ensure they are properly torqued and are not damaged (See “Inspect / Torque Bolts”
_______
Inspect the teeth and blade bolts. Ensure they are properly torqued and are not damaged (See “Inspect / Torque
Inspect Blades
_______
Inspect blade wear. Rotate or replace if rounded more than 0.25” (See “Blade Maintenance” on page 18).
Inspected By: _______________________________________________ Date:_____________________
DAILY
Visual Inspection
_______
Ensure the identification plate is present and is legible. Replace if necessary.
_______
Inspect all tool decals and ensure they are legible. Replace if missing or illegible. Contact LaBounty customer
service for replacements.
_______
Visually inspect the structure of the attachment. If damage is found, do not use the attachment. Repair
immediately.
_______
Inspect all welds and ensure there are no cracks or damage. If damage is found, do not use the attachment.
Repair immediately.
_______
Visually inspect all hydraulic hoses and connections. Ensure they are not damaged.
Inspect Hardware
_______
Check the play between the pins and bushings on the bracket connection. If the play is greater than 0.6 mm,
replace the bushings and pins.
_______
Check all hydraulic connection hardware. Ensure they are properly torqued and are not damaged (see “Inspect /
Inspected By: _______________________________________________ Date:_____________________