MRP Mobile Rotating Pulverizer Operation & Maintenance Manual | 11
•
Turn the rotation flow control knob clockwise to increase flow.
•
Turn the rotation flow control knob counter clockwise to decrease flow.
STORING THE ATTACHMENT
1.
Lubricate all parts. See “Lubrication” on page 17.
2.
Fully open the jaws.
3.
Insert the transport pin.
4. Lower the attachment to the ground and secure it on wooden supports, orienting it horizontally.
5.
Turn off the excavator and relieve any trapped pressure in the hydraulic system. Lock-out / Tag-out the hydraulic
power source.
Do not connect or disconnect hydraulic lines while
they are pressurized. Escaping fluid under pressure
can penetrate the skin, causing serious injury.
Trapped hydraulic pressure may be present after
the base machine is shut off. Extreme caution must
be taken when removing hydraulic hoses or lines.
Injury or death could result.
6. Disconnect and plug all hydraulic lines.
7.
Store the attachment in a protected place, where it will be isolated from shocks, stress, damage and corrosive
substances.
Note: Do not store the attachment in a high humidity environment or in an environment with extreme temperature
shifts.