background image

6

• This system is designed to be used only on vehicles with a 12 volt DC battery system. Do not 

connect to a 6 volt or 24 volt battery system.

• This system is not designed to be used as a replacement for a vehicular battery. Do not attempt to 

operate a vehicle that does not have a battery installed.

• Excessive engine cranking can damage a vehicle’s starter motor. If the engine fails to start after 

the recommended number of attempts, discontinue jump-start procedures and look for other 

problems that may need to be corrected.

• Do not use this jump starter on a watercraft. It is not qualified for marine applications.

• Although this unit contains a non-spillable battery, it is recommended that unit be kept upright 

during storage, use and recharging. To avoid possible damage that may shorten the unit’s 

working life, protect it from direct sunlight, direct heat and/or moisture.

SPECIFIC SAFETY INSTRUCTIONS FOR THE USB PORTS

• Do not insert foreign objects into the USB Ports.

• Do not attach USB hubs or more than one personal electronic device to each USB Port.

• Do not use this unit to operate appliances that require more than 3.1A (5V) to operate from each 

of the USB Ports. 

• Some household USB-powered electronics will not operate with this unit.

SPECIFIC SAFETY INSTRUCTIONS FOR COMPRESSORS

CAUTION 

– TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:

• Never leave the compressor unattended while in use.

• Do not operate compressor continuously for longer than approximately 10 minutes, depending 

on ambient temperatures, as it may overheat. This could damage the compressor. Follow the 

instructions in the “Portable Compressor” section.

WARNING

 – BURST HAZARD: Bursting articles can cause serious injury.

• Carefully follow instructions on articles to be inflated.

• Never exceed the recommended pressure listed in instructions on articles to be inflated. If no 

pressure is given, contact article manufacturer before inflating. 

• Monitor the pressure at all times on the LCD screen.

FIRST AID

When working with lead acid batteries, always make sure immediate assistance is available in case 

of accident or emergency.
Always have protective eyewear when using this product: contact with battery acid may cause 

blindness and/or severe burns. Be aware of first aid procedures in case of accidental contact with 

battery acid.
Have plenty of fresh water and soap nearby in case battery acid contacts skin.

• 

Skin:

 If battery acid comes in contact with skin, rinse immediately with water, then wash 

thoroughly with soap and water. If redness, pain, or irritation occurs, seek immediate medical 

attention.

• 

Eyes: 

If battery acid comes in contact with eyes, flush eyes immediately, for a minimum of 15 

minutes and seek immediate medical attention.

• 

LCD liquid crystal display: 

If liquid crystal comes in contact with your skin: Wash area off 

completely with plenty of water. Remove contaminated clothing. If liquid crystal gets into your 

eye: Flush the affected eye with clean water and then seek medical attention. If liquid crystal is 

swallowed: Flush your mouth thoroughly with water. Drink large quantities of water and induce 

vomiting. Then seek medical attention.

SAVE THESE INSTRUCTIONS

INTRODUCTION

Congratulations on purchasing your new 

JUMP iT

®

 Portable Power Station. 

Read this 

Instruction Manual and follow the instructions carefully before using this unit. 

OVERVIEW

Common Actions and Unit Responses

The following actions turn the unit on and activate the LCD screen:

Press the LED Area Light 

Power Button. 

(Refer to the 

"LED Area Light" section.)

A beep will sound and the Area Light will turn on. The 

backlight will turn on for 10 seconds (only). The LCD screen 

will continue to display the Battery Status Icon and Battery 

Voltage Indicator. The unit remains on until the LED Area 

Light Power Button is pressed again to turn it off.

Press the USB Power 

Button. 

(Refer to the "USB 

Ports" section.)

A beep will sound and the USB Ports will turn on. The 

backlight will turn on for 10 seconds (only). The LCD 

screen will display the Battery Status Icon, Battery Voltage 

Indicator, and the USB Icon; indicating the three USB Ports 

are active. The unit remains on until the USB Power Button 

is pressed again to turn it off.

Press the Compressor 

Power Button. 

(Refer to 

the "Portable Compressor" 

section.)

A beep will sound and the backlit LCD screen will display 

the Battery Status Icon, "XXX" PSI and the Compressor Icon. 

If no further actions are taken after 1 minute, the unit will 

display the Battery Status Icon and Battery Voltage Indicator 

for 10 seconds before automatically turning off.

If the Jump Starter Switch 

has been turned to the 

on position and the 

clamps are not connected 

to a battery

 (refer to the 

“Jump-Starting Your Vehicle” 

section) ...

... a two-second warning will sound every 10 seconds. The 

backlit LCD screen will display the Battery Status Icon, 

Battery Voltage Indicator, the Clamp Icons, and the “+” and 

”–” signs. The Alarm Icon and the Jump Starter Icon will 

flash. The unit remains on until the Jump Starter Power 

Switch is switched off and then displays the battery status 

icon and the voltage of digital display for 10 seconds before 

automatic shut down.

If the clamp connections 

to the battery’s positive 

and negative terminals are 

reversed

 (refer to the "Jump 

Starter" section) 

… the backlit LCD screen will display the Battery Status Icon, 

Battery Voltage Indicator, and the Clamp Icons. The Alarm 

Icon, the “+” and ”–” signs and the Reverse Polarity Icons 

will flash and the unit will sound a warning continuously 

until the clamps are disconnected from the battery.

Whenever the clamps 

are properly connected 

to a battery 

(refer to the 

“Jump-Starting Your Vehicle” 

section) ...

... a beep will sound and the backlit LCD screen will display 

the Battery Status Icon, Battery Voltage Indicator, the Clamp 

Icons, and the “+” and ”–” signs. The Jump Starter Icon will 

flash. The unit remains on until the clamps are

disconnected from the battery.

When the unit is charging  

or recharging using 

the built-in 120 Volt 

AC Charger 

(refer to the 

"Charging/Recharging" 

section) 

… the backlight will turn on for 10 seconds (only). The 

LCD screen will continue to display the Battery Status Icon 

and Battery Voltage Indicator. The bars on the Battery 

Status Icon will change from empty to solid (bottom to 

top) repeatedly.

Note:

  The unit will automatically power off once ALL the functions are turned off.

VIEWING BATTERY STATUS

The Battery Status Icon and Battery Voltage Indicator indicate the battery charge level as follows.

• If the battery charge level is at full capacity, four solid bars will display.

• If the battery is partially charged, two or three solid bars will display.

• If the battery is nearly empty, one solid bar will display. The unit should be charged at this time.

• If the battery is completely empty, four blank bars will display. The unit MUST be charged at this 

time or the unit’s built-in low voltage protection will activate. The empty Battery Status Icon will 

flash for a short period of time before automatic shut down. The unit will not operate until the 

battery is recharged.

CHARGING/RECHARGING

This unit is delivered in a partially charged state – you must fully charge it before using it for the 

first time. Initial AC charge should be for 40 hours or until the Battery Status Icon shows 4 solid bars.
Lead-acid batteries require routine maintenance to ensure a full charge and long battery life. 

All batteries lose energy from self-discharge over time and more rapidly at higher temperatures. 

Therefore, batteries need periodic charging to replace energy lost through self-discharge. When 

the unit is not in frequent use, manufacturer recommends the battery should be recharged at least 

every 30 days and after each use.

CAUTION –

 RISK OF PROPERTY DAMAGE:

 Failure to keep the battery charged will cause 

permanent damage and result in poor jump starting performance.

IMPORTANT NOTES:

• Recharging the battery after each use will prolong battery life; frequent heavy discharges 

between recharges and/or overcharging will reduce battery life.

• Make sure all other unit functions are turned off during recharging, as this can slow the 

recharging process.

• If you know the unit is discharged, but the battery icon displays four solid bars as if the unit is 

fully charged when connected to a charging power source, this may be due to the internal battery 

having high impedance. The manufacturer suggests leaving the unit charging for a period of 40 

hours using the built-in AC charger before use. 

Charging/Recharging Using the Built-In 120 Volt AC 

Charger and AC Extension Cord (not included)

 1.  Lift the protective cover of the built-in 120 Volt AC Charger (refer to the “Features section to 

locate). Connect an extension cord to the unit. Plug the other end of the cord into a standard 

120-volt AC wall outlet. When the unit is properly connected to an AC power source, the LCD 

screen will display the following:

  The bars on the Battery Status Icon represent the charge level of the unit’s internal battery. The 

bars on the Battery Status Icon will change from empty to solid (bottom to top) repeatedly to 

indicate the unit is charging. The backlight will turn on for 10 seconds (only).

 2.  Charge for approximately 40 hours or until the Battery Status Icon shows 4 solid bars.

 3.  When charging is complete, unplug the AC extension cord from the AC outlet and then 

disconnect it from the unit.

Summary of Contents for JUMP iT J5C09D

Page 1: ...16 ...

Page 2: ...L JUMPiT ENERGÍAPORTÁTIL MANUAL DE INSTRUCCIÓN SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE CONSERVE ESTE MANUAL PARA FUTURAS CONSULTAS 2019 Baccus Global LLC Boca Raton FL 33432 877 571 2391 J5C09D English page 5 Español pagina 11 BC x ...

Page 3: ...2 FEATURES CARACTERÍSTICAS 1 6 7 8 2 4 5 9 10 3 ...

Page 4: ...sion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or a...

Page 5: ... DE LA FUNCIÓN ALARM ICON ICONO DE ALARMA REVERSE POLARITY ICONS ICONOS DE POLARIDAD INVERSA CLAMP ICONS ICONOS DE PINZAS COMPRESSOR PRESSURE INDICATOR INDICADOR DE PRESIÓN DEL COMPRESOR USB ICON ICONO DE USB COMPRESSOR ICON ICONO DEL COMPRESOR JUMP STARTER ICON ICONO DEL PUENTE AUXILIAR DE ARRANQUE FAULT ICON ICONO DEL FALLO VOLTAGE INDICATOR INDICADOR DEL VOLTAJE ...

Page 6: ...51 100 101 150 0 7 6m 7 6 15 2m 15 2 30 4m 30 4 45 7m 240V 0 50 51 100 101 200 201 300 0 15 2m 15 2 30 4m 30 4 60 9m 60 9 91 4m Ampere Rating Extension Cord Length More Not more 0 25 26 50 51 100 101 150 Than Than American Wire Gauge AWG 0 6 18 16 16 14 6 10 18 16 14 12 10 12 16 16 14 12 12 16 14 12 Not Recommended When an extension cord is used make sure that the pins of extension cord are the sa...

Page 7: ... Starter Switch has been turned to the on position and the clamps are not connected to a battery refer to the Jump Starting Your Vehicle section a two second warning will sound every 10 seconds The backlit LCD screen will display the Battery Status Icon Battery Voltage Indicator the Clamp Icons and the and signs The Alarm Icon and the Jump Starter Icon will flash The unit remains on until the Jump...

Page 8: ...xcept for positive grounded systems CAUTION TO REDUCE THE RISK OF PROPERTY DAMAGE Vehicles that have on board computerized systems may be damaged if vehicle battery is jump started Before jump starting this type of vehicle read the vehicle manual to confirm that external starting assistance is advised Excessive engine cranking can damage the vehicle s starter motor If the engine fails to start aft...

Page 9: ...attery should last the service life of the unit Service life is dependent on a number of factors including but not limited to the number of recharge cycles and proper care and maintenance of the battery by the end user Contact manufacturer for any information you may need SAFE BATTERY DISPOSAL Contains a maintenance free sealed non spillable lead acid battery which must be disposed of properly Rec...

Page 10: ... 60Hz 13W Area Light 1 white LED USB Ports 3 1A max 5V DC Compressor Maximum Pressure 120 PSI JUMP iT and Sure Fit are registered U S trademarks owned or licensed by Baccus Global LLC Imported by Baccus Global LLC One City Centre 1 North Federal Highway Suite 200 Boca Raton FL 33432 www Baccusglobal com 1 877 571 2391 RD051519 ...

Page 11: ...10 ...

Page 12: ...ría muestre 4 barras sólidas antes de usarlo por primera vez No se puede exceso de carga la unidad con el método de carga de CA Para recargar esta unidad utilice sólo el cargador incorporado CA Todas las funciones deben apagarse cuando la unidad se está cargando o no está en uso Asegúrese de que todos los interruptores estén en la posición de apagado OFF antes de realizar la conexión a una fuente ...

Page 13: ...retroiluminada PRIMEROS AUXILIOS Cuando trabaje con baterías de plomo ácido asegúrese de que siempre haya ayuda inmediata disponible en caso de accidente o emergencia Utilice siempre protección para los ojos al emplear este producto el contacto con el ácido de la batería puede producir ceguera o quemaduras graves Conozca los procedimientos de primeros auxilios para el caso de contacto accidental c...

Page 14: ...egra del negativo al bastidor o a un componente metálico no móvil y sólido o una parte de la carrocería Nunca fije la pinza directamente al terminal del negativo de la batería o a una pieza móvil Refiera al manual del dueño del automóvil 5 Procedimiento para arrancar SISTEMAS CON POSITIVO A TIERRA Nota En el caso poco habitual de que el vehículo que se debe arrancar tenga un sistema de positivo a ...

Page 15: ... sección de las instrucciones de seguridad específicas para compresores de este manual de la instrucción PRECAUCIÓN PARA REDUCIR EL RIESGO DE DAÑOS MATERIALES Cuando el compresor es operado a un PSI baja la unidad puede comenzar en baja y acelerar gradualmente Cuando el compresor es operado a más alto PSIs la unidad puede funcionar normalmente durante varios minutos luego decelerar durante unos mi...

Page 16: ...encendido del compresor para apagar el compresor Reinicie después de un período de enfriamiento de 30 minutos aproximadamente Compruebe que la unidad tiene una carga completa Recargue la unidad en caso de necesidad ACCESORIOS Accesorios recomendados para uso con esta unidad puede ser disponibles a través del fabricante Si necesita ayuda con respecto a los accesorios por favor póngase en contacto c...

Reviews: