6

7

 

Make sure all other unit functions are turned off during recharging, as this can slow the recharging process.

 

If the the battery is overly discharged and the green LED lights when the charger is plugged in, this indicates the battery is at a high impedance stage. If 

this occurs, recharge the unit and leave it charging for a period of 24-48 hours before use.

Charging/Recharging Using the 120 Volt AC Charger and  a Standard Household Extension Cord (not included)

  1.  Lift the AC adapter cover located on the back of the unit and connect an extension cord to the unit. Plug the other end of the 

cord into a standard 120 volt AC wall outlet.

  2.  Charge until two red and one green LED battery status indicators light or flash.

  3.   Once fully charged, disconnect the extension cord. 

Notes: 

The unit cannot be overcharged using this method.

 

The unit will not charge if the inverter power switch is turned on.

12 Volt DC Charging Method

Charging the unit from an external 12 volt DC power source requires the use of the 12 volt DC adapter (optional accessory). This 

adapter has a male DC connector at each end.

  1.  Insert the gold-tipped 12 volt DC charging adapter plug into the vehicle’s 12 volt DC accessory outlet.

  2.  Insert the silver-tipped end plug into the 12 volt DC accessory outlet on the front panel of the unit.

  3.  Charge the unit until the green FULL indicator lights when the Battery Power Level Button is pressed (with the adapter 

unplugged from the unit). DO NOT CHARGE MORE THAN 6 HOURS MAXIMUM USING THIS METHOD. 

  4.  When charging is complete, remove the charging cord and store in a safe place.

Notes: 

Some vehicles require that the ignition be switched to the accessory outlet position in order to power the accessory outlet.

 

DO NOT LEAVE THE UNIT UNATTENDED WHEN CHARGING USING THIS METHOD.

JUMP-STARTER

This Jump-Starter is equipped with an On/Off power switch. Once the connections are properly made, turn the switch on to jump-

start the vehicle.

  1.   Turn off vehicle ignition and all accessories (radio, A/C, lights, connected cell phone chargers, etc.). Place vehicle in “park” and 

set the emergency brake. 

  2.  Make sure the Jump-Starter power switch is turned to off.

  3.  Remove jumper clamps from clamp tabs. Connect the red clamp first, then the black clamp. 

  4.  Procedure for jump-starting a NEGATIVE GROUNDED SYSTEM (negative battery terminal is connected to chassis) 

(MOST COMMON)

4a.  Connect positive (+) red clamp to vehicle battery’s positive terminal.

4b.   Connect negative (–) black clamp to chassis or a solid, non-moving, metal vehicle component or body part. Never clamp directly to 

negative battery terminal or moving part. Refer to the automobile owner’s manual.

  5.  Procedure for jump-starting POSITIVE GROUND SYSTEMS

Note: 

In the rare event that the vehicle to be started has a Positive Grounded System (positive battery terminal is connected to chassis), replace steps 4a 

and 4b above with steps 5a and 5b, then proceed to step 6.

5a.  Connect negative (–) black clamp to vehicle battery’s negative terminal.

5b.   Connect positive (+) red clamp to vehicle chassis or a solid, non-moving, metal vehicle component or body part. Never clamp directly 

to Positive battery terminal or moving part. Refer to the automobile owner’s manual.

  6.  When clamps are connected properly, turn the Jump-Starter power switch to ON.

  7.  Turn ON the ignition and crank the engine in 5-6 second bursts until engine starts.

  8.  Turn the Jump-Starter power switch back to the OFF position.

  9.  Disconnect the negative (–) engine or chassis clamp first, then disconnect the positive (+) battery clamp.

WARNING: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE:

• FOLLOW ALL SAFETY INSTRUCTIONS FOUND IN THE “SPECIFIC SAFETY INSTRUCTIONS FOR JUMP STARTERS” 

SECTION OF THIS INSTRUCTION MANUAL.

• This power system is to be used ONLY on vehicles with 12 volt DC battery systems.

• Never touch red and black clamps together — this can cause dangerous sparks, power arcing, and/or explosion.

• After use, turn the Jump-Starter power switch off.

CAUTION: TO REDUCE THE RISK OF PROPERTY DAMAGE:

• Vehicles that have on-board computerized systems may be damaged if vehicle battery is jump-started. Before jump-starting this 

type of vehicle, read the vehicle manual to confirm that external-starting assistance is advised.

• Excessive engine cranking can damage the vehicle‘s starter motor. If the engine fails to start after the recommended number of 

attempts, discontinue jump-start procedure and look for other problems that need to be corrected.

• If the connections to the battery’s positive and negative terminals are incorrect, the Reverse Polarity Indicator will light and the 

unit will sound a beep.  Disconnect clamps and reconnect to battery with correct polarity.

• Place this unit as far away from the battery as cables permit.

• Never allow battery acid to come in contact with this unit.

• Do not operate this unit in a closed area or restrict ventilation in any way.

• This system is designed to be used only on vehicles with a 12 volt DC battery system. Do not connect to a 6 volt or 24 volt battery system.

• This system is not designed to be used as a replacement for a vehicular battery. Do not attempt to operate a vehicle that does not 

have a battery installed.

• Excessive engine cranking can damage a vehicle’s starter motor. If the engine fails to start after the recommended number of 

attempts, discontinue jump-start procedures and look for other problems that may need to be corrected.

• Do not use this jump-starter on a watercraft. It is not qualified for marine applications.

• Although this unit contains a non-spillable battery, it is recommended that unit be kept upright during storage, use and 

recharging. To avoid possible damage that may shorten the unit’s working life, protect it from direct sunlight, direct heat and/or 

moisture.

FIRST AID

 SKIN:

 If battery acid contacts skin or clothing, wash immediately with soap and water for at least 10 minutes. If redness, pain, or 

irritation occurs, seek immediate medical attention.

 

EYES: 

If battery acid comes in contact with eyes, flush eyes immediately, for a minimum of 15 minutes and seek immediate 

medical attention. 

SPECIFIC SAFETY INSTRUCTIONS FOR INVERTERS

WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK:

• Do not connect to AC distribution wiring.

• Do not make any electrical connections or disconnections in areas designated as IGNITION PROTECTED. This inverter is NOT 

approved for ignition protected areas.

• Never immerse the inverter in water or any other liquid, or use when wet.

• Do not insert foreign objects into the inverter’s outlets.

WARNING: TO REDUCE THE RISK OF FIRE:

• Do not operate near flammable materials, fumes or gases.

• Do not expose to extreme heat or flames.

CAUTION: TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE: 

• Disconnect appliance plug from inverter outlet before attempting any repairs to the appliance.

• Do not attempt to connect the inverter while operating your vehicle. Not paying attention to the road may result in a serious 

accident.

• Always use the inverter where there is adequate ventilation. Do not block ventilation slots.

• Always turn the inverter off when not in use.

• Keep in mind that this inverter will not operate high wattage appliances or equipment that produce heat, such as hair dryers, 

microwave ovens and toasters.

• DO NOT OPEN THE UNIT — there are no user-serviceable parts inside. Opening the inverter will void manufacturer’s warranty.

• Do not use this inverter with medical devices. It is not tested for medical applications.

• Operate inverter only as described in this Instruction Manual.

SAVE THESE INSTRUCTIONS

INTRODUCTION

Congratulations on purchasing your new 500 Amp Jump Starter with Compressor and Power Inverter. Read this Instruction Manual 

and follow the instructions carefully before using this unit. 

CHARGING/RECHARGING

Lead-acid batteries require routine maintenance to ensure a full charge and long battery life. All batteries lose energy from  

self-discharge over time and more rapidly at higher temperatures. Therefore, batteries need periodic charging to replace energy  

lost through self-discharge. When the unit is not in frequent use, manufacturer recommends the battery be recharged at least 

every 30 days.

WARNING: Never attempt to use the AC and DC charging methods at the same time.
CAUTION: RISK OF PROPERTY DAMAGE: 

Failure to keep the battery charged will cause permanent damage and result in poor 

jump starting performance.

Notes: 

This unit is delivered in a partially charged state – you must fully charge it upon purchase and before using it for the first time. Initial AC charge should be 

for 40 hours.

 

Recharging battery after each use will prolong battery life; frequent heavy discharges between recharges and/or overcharging will reduce battery life. The 

battery can be recharged using either the Built-In 120 volt AC Charger or the DC charging adapter.

J5CP_ManualENSP_051413.indd   6-7

1/16/2014   9:46:23 AM

Summary of Contents for J5CP

Page 1: ...00ACON COMPRESORYINVERSORDEPODER MANUAL DE INSTRUCCI N SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE CONSERVE ESTE MANUAL PARA FUTURAS CONSULTAS 2013 Baccus Global LLC Boca Raton FL 33432 Customer...

Page 2: ...E THE RISK OF FIRE ELECTRIC SHOCK BURST HAZARD OR INJURY TO PERSONS OR PROPERTY Avoid dangerous environments Don t use appliances in damp or wet locations Don t use appliances in the rain Keep childre...

Page 3: ...the POSITIVE RED clamp to the vehicle chassis or engine block away from the battery Do not connect the clamp to the carburetor fuel lines or sheet metal body parts Connect to a heavy gauge metal part...

Page 4: ...ne fails to start after the recommended number of attempts discontinue jump start procedure and look for other problems that need to be corrected If the connections to the battery s positive and negat...

Page 5: ...harge this unit fully after each use 120 VOLT AC PORTABLE POWER SUPPLY This unit has a built in Power Inverter that provides up to 200 watts of AC power This inverter is an electronic device that conv...

Page 6: ...ite 210 Boca Raton FL 33432 877 571 2391 RD051413 WARNING TO REDUCE THE RISK OF INJURY OR PROPERTY DAMAGE FOLLOW ALL SAFETY INSTRUCTIONS FOUND IN THE SPECIFIC SAFETY INSTRUCTIONS FOR COMPRESSORS SECTI...

Page 7: ...a modificaci n incorrectos de herramientas o equipos pueden provocar lesiones graves y da os a la propiedad Las herramientas y los equipos est n dise ados para usos determinados Fabricante recomienda...

Page 8: ...ntre s o con otro conductor met lico com n esto podr a provocar da os a la unidad o crear un riesgo de chispas explosi n La protecci n del interruptor de corte por falla a tierra GFCI debe aplicarse a...

Page 9: ...negativo al terminal del negativo de la bater a del veh culo 5b Conecte la pinza roja del positivo al bastidor del veh culo o a un componente met lico no m vil y s lido o una parte de la carrocer a Nu...

Page 10: ...dos hasta que arranque 8 Coloque el interruptor de encendido del puente auxiliar de arranque en la posici n de apagado off nuevamente 9 Desconecte la pinza del negativo del motor o bastidor primero y...

Page 11: ...ntacto con el fabricante al 877 571 2391 COMPRESOR PORT TIL El compresor incorporado de CC de 12 voltios es el compresor de ltima generaci n para los neum ticos de todos los veh culos remolques y art...

Page 12: ...os fusibles y bater as defectos a consecuencias de desgaste normal accidentes da os y perjuicios sufridos durante el env o y manejo alteraciones reparaciones o uso no autorizado negligencia abuso y si...