HP12 User
Manual ◄ 9
HTMA / EHTMA REQUIREMENTS
TOOL TYPE
HTMA
HYDRAULIC SYSTEM REQUIREMENTS
TYPE I
TYPE II
TYPE RR
TYPE III
Flow range
4-6 GPM
(15-23 LPM)
7-9 GPM
(26-34 LPM)
9-10.5 GPM
(34-40 LPM)
11-13 GPM
(42-49 LPM)
Nominal operating pressure
(At the power supply outlet)
1500 psi
(103 bar)
1500 psi
(103 bar)
1500 psi
(103 bar)
1500 psi
(103 bar)
System relief valve setting
(At the power supply outlet)
2100-2250 psi
(145-155 bar)
2100-2250 psi
(145-155 bar)
2200-2300 psi
(152-159 bar)
2100-2250 psi
(145-155 bar)
Maximum back pressure
(At tool end of the return hose)
250 psi
(17 bar)
250 psi
(17 bar)
250 psi
(17 bar)
250 psi
(17 bar)
Measured at a max fl uid viscosity of:
(At minimum operating temperature)
400 ssu*
(82 centistokes)
400 ssu*
(82 centistokes)
400 ssu*
(82 centistokes)
400 ssu*
(82 centistokes)
Temperature: Suffi cient heat rejection capacity to limit
maximum fl uid temperature to:
(At maximum expected ambient temperature)
140° F
(60° C)
140° F
(60° C)
140° F
(60° C)
140° F
(60° C)
Minimum cooling capacity at a temperature diff erence of
between ambient and fl uid temps
3 hp
(2.24 kW)
40° F
(22° C)
5 hp
(3.73 kW)
40° F
(22° C)
6 hp
(5.22 kW)
40° F
(22° C)
7 hp
(4.47 kW)
40° F
(22° C)
Note:
Do not operate the tool at oil temperatures above 140° F (60° C). Operation at higher temperatures can cause operator
discomfort at the tool.
Filter minimum full-fl ow fi ltration
25 microns
25 microns
25 microns
25 microns
Sized for fl ow of at least:
(For cold temp startup and maximum dirt-holding capacity)
30 GPM
(114 LPM)
30 GPM
(114 LPM)
30 GPM
(114 LPM)
30 GPM
(114 LPM)
Hydraulic fl uid, petroleum based (premium grade, anti-
wear, non-conductive) Viscosity (at minimum and maximum
operating temps)
100-400 ssu
(20-82
centistokes)
100-400 ssu
(20-82
centistokes)
100-400 ssu
(20-82
centistokes)
100-400 ssu
(20-82
centistokes)
Note:
When choosing hydraulic fl uid, the expected oil temperature extremes that will be experienced in service determine the most
suitable temperature viscosity characteristics. Hydraulic fl uids with a viscosity index over 140 will meet the requirements over a wide
range of operating temperatures.
*SSU = Saybolt Seconds Universal
CLASSIFICATION
EHTMA
HYDRAULIC SYSTEM
REQUIREMENTS
B
C
D
Flow range
3.5-4.3 GPM
(13.5-16.5
LPM)
4.7-5.8 GPM
(18-22 LPM)
7.1-8.7 GPM
(27-33 LPM)
9.5-11.6 GPM
(36-44 LPM)
11.8-14.5 GPM
(45-55 LPM)
Nominal operating pressure
(At the power supply outlet)
1870 psi
(129 bar)
1500 psi
(103 bar)
1500 psi
(103 bar)
1500 psi
(103 bar)
1500 psi
(103 bar)
System relief valve setting
(At the power supply outlet)
2495 psi
(172 bar)
2000 psi
(138 bar)
2000 psi
(138 bar)
2000 psi
(138 bar)
2000 psi
(138 bar)
Note:
These are general hydraulic system requirements. See tool specifi cation page for tool specifi c requirements.
HTMA / EHTMA REQUIREMENTS