ACS IS nOT RESPOnDInG TO mECHAnICAl KEy ROTATIOn AnD
InSERTIOn OF uSER TAGS
If the lock is still not responding make sure that batteries are installed
properly (check batteries polarity).
not working still? replace batteries.
RED lED IS BlInKInG EvERy 10 SECOnDS
This is low the low battery
indication, please replace batteries.
TROuBlE SHOOTInG
& TIPS
lOCK wAS nOT ClOSED PROPERly wHEn InSERTInG THE uSER TAG
if this situation accured it means that something is interfering with the electromechanical latch movement.
insert user tag again to open the lock.
place shackle properly in its place to allow movement of the latch.
insert user tag again to close the latch.
note: When electromechanical latch is not closed properly an “error” notification will be sounded.
lOST yOuR uSER TAGS
it is possible to erase tags from acs database, refer to “deleting a specific user” section of user manual.
it is also possible to erase specific tags using “stanley guard pc management software” or smart phone
application (bluetooth version).
lOCK lEFT OPEn, mASTER uSER DOESn'T HAvE HIS uSER TAG
option 1 - rotate key to “pairing position” and then to “Key in” position. these operations will open a 10 seconds
time window, during this period of time press the push button until the electromechanical latch is closed.
option 2- the electromechanical latch is closed automatically when master user places the lock in temporary
authorizations freeze mode refer to this section in the user manual.
PC uSB COnnECTIOn IS nOT ESTABlISHED
make sure that the mechanical key position is “communication” mode (refer to pc connection section).
make sure that the usb cable is not corrupted or damaged.
09
ACS SPECS
Application
high security electronic lock for access control.
Dimensions
105 x 150 x 37 mm
weight
1550 gr including batteries
Keys
mech passive rfid
Standards
bs en 12320
Battery Type
cr123a X 2
nominal Operation voltage
6v
Battery life Cycle
(Average) 6 months
Battery Capacity
1700 mah
IP
56
maximum users
100
Communication Interface
usb 2.0, bluetooth (optional)
max Bluetooth range
15m
log
registration of time and events (unlock, lock, pairing,
Delete,Authorizations freeze/unfreeze)
log Capacity
1000 records
RFID Reader Frequency
125Khz
Operating temperature
(-20) - (+85) c
Storage temperature
(-30) - (+85) c
FCC ID
rlbacs320000; rlbacs321000 (acs-bt)
Patent application number
nOTE: In order to review a list of supported smartphones (for ACS-BT),
refer to the Andriod play market or Apple store.
Standards
en 609050-1
en 609050-22
ul 60950-1
csa cs22.2 60950-1
en 301489
en 300330
as/nzs cispr 22
vcci v-3
fcc part 15, sub-part b, c
fcc id:XXXacs320000
fcc id:XXXacs321000
this device complies with part 15 of the fcc rules.
operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.