OPERATING INSTRUCTIONS

Test Firing Heater

Test fire heater, following the lighting instructions on heater case.  
Leak test all gas connections with soapy water.  Soap bubbles indicate 
gas leakage. DO NOT use a match to test for gas leaks.
WARNING: Improper adjustment, alteration, service or maintenance 
can cause injury or property damage. Any modifications or adjustments 
made to product without prior authority from the manufacturer will 
void any warranty claims. Read the operating and maintenance 
instructions thoroughly before servicing this equipment.

Troubleshooting  

 

Problem

Possible Causes

Solutions

Fan does not start

Power not on

Turn power on

Defective switch

Repair or replace

Defective fan

Repair or replace

Burner does not light

Spark igniter not operating

Replace

Gas cylinder not turned on

Check cylinder

Gap at electrode too large

Adjust

Flame burns out after ignition

Defective safety devices

Contact manufacturer or authorised service personnel

Flame unstable and yellow

Air blockage

Clean air intake

Contact manufacturer or authorised service personnel

Lighting Instructions

* Remove any transit protection material.

1.   Connect the hose and regulator.
2.   Open the gas cylinder valve, check for leaks with a soapy water 

solution.

3.   Turn on fan by pressing Fan Switch (item 1) to ON.
 

WARNING: If the fan does not start DO NOT proceed with 
ignition.

4.   Press Gas Button (item 2) and keep depressed. At the same time 

continually press the Igniter Button (item 3) until burner lights. 
When burner lights keep button depressed for 10-20 seconds then 
release, the burner should stay alight.  
If burner fails to remain alight turn gas cylinder valve ‘OFF’ 
and Fan Switch (item 1) to ‘OFF’. Wait 5 minutes then repeat 
procedure from step 2. 

5.   To turn heater off, turn gas cylinder valve ‘OFF’ and 

Fan Switch (item 1) to ‘OFF’. 

Emergency Shut Down

Close cylinder valve. Switch fan off.

POL CYLINDER CONNECTION DEVICE

Item 1.   Fan Switch

Item 2.   Gas Button

Item 3.   Igniter Button

Summary of Contents for EH6883

Page 1: ...03004 02 13 For service spare parts or product information please contact Smart Marketing Group Pty Ltd AUST 1300 660 457 N Z 0800 474 876 MODEL NO EH6883 Propane Electric Blow Heater...

Page 2: ...If you smell gas 1 Shut off the gas to the appliance 2 Extinguish any open flame 3 If odour continues immediately call your gas supplier Do not store or use gasoline or other flammable vapour and liq...

Page 3: ...ry or component will be replaced or repaired SMG reserves the right to replace defective parts of the product with parts and components of similar quality grade and composition where an identical part...

Page 4: ...and composition where an identical part or component is not available Products presented for repair may be replaced by refurbished products of the same type rather than being repaired Refurbished par...

Page 5: ...n a level and adequate footing and be readily accessible 4 The gas manifold supply pressure must be regulated at 150 kPa utilising only the regulator supplied with the heater 5 The appliance must be i...

Page 6: ...oint Wait five minutes before re testing and use a soapy water solution to check the joint If bubbles appear the connection will need to be re tightened Clothing or other flammable materials should no...

Page 7: ...burns out after ignition Defective safety devices Contact manufacturer or authorised service personnel Flame unstable and yellow Air blockage Clean air intake Contact manufacturer or authorised servic...

Page 8: ...n Blades This work should be carried out by the Manufacturer or by authorised Service Personnel Method Remove Heating Unit from outer casing as described above Burner Ports can then be cleaned using a...

Page 9: ...or 3 Internal wiring 4 Fan blade 5 Burner 6 Handle for transport 7 Internal body 8 External body 9 Hot air output 10 Burner air intake 11 Igniter button 12 Gas inlet connection 13 Fan switch 14 Electr...

Page 10: ...justments Pilot Nil Aeration Fixed Ignition Spark Gap 6mm ELECTRICAL The heater is supplied with a 220 240V AC electrical power cord with a 3 pin plug This plug must only be connected to an earthed po...

Page 11: ...nditions DO NOT use the heater within one metre 1m of any water source Always ensure that the power cord is fully extended and NOT in contact with any part of the heater Never use the heater if any pa...

Page 12: ...tomer Service AUST 1300 660 457 NZ 0800 474 876 Hours of operation Monday to Friday 8 30am 5 30pm AEST Do not return to place of purchase Keep your purchase receipt this will be required to make any c...

Reviews: