6
7
OPERATING INSTRUCTIONS
Test Firing Heater
Test fire heater, following the lighting instructions on heater case.
Leak test all gas connections with soapy water. Soap bubbles indicate
gas leakage. DO NOT use a match to test for gas leaks.
WARNING: Improper adjustment, alteration, service or maintenance
can cause injury or property damage. Any modifications or adjustments
made to product without prior authority from the manufacturer will
void any warranty claims. Read the operating and maintenance
instructions thoroughly before servicing this equipment.
Troubleshooting
Problem
Possible Causes
Solutions
Fan does not start
Power not on
Turn power on
Defective switch
Repair or replace
Defective fan
Repair or replace
Burner does not light
Spark igniter not operating
Replace
Gas cylinder not turned on
Check cylinder
Gap at electrode too large
Adjust
Flame burns out after ignition
Defective safety devices
Contact manufacturer or authorised service personnel
Flame unstable and yellow
Air blockage
Clean air intake
Contact manufacturer or authorised service personnel
Lighting Instructions
* Remove any transit protection material.
1. Connect the hose and regulator.
2. Open the gas cylinder valve, check for leaks with a soapy water
solution.
3. Turn on fan by pressing Fan Switch (item 1) to ON.
WARNING: If the fan does not start DO NOT proceed with
ignition.
4. Press Gas Button (item 2) and keep depressed. At the same time
continually press the Igniter Button (item 3) until burner lights.
When burner lights keep button depressed for 10-20 seconds then
release, the burner should stay alight.
If burner fails to remain alight turn gas cylinder valve ‘OFF’
and Fan Switch (item 1) to ‘OFF’. Wait 5 minutes then repeat
procedure from step 2.
5. To turn heater off, turn gas cylinder valve ‘OFF’ and
Fan Switch (item 1) to ‘OFF’.
Emergency Shut Down
Close cylinder valve. Switch fan off.
POL CYLINDER CONNECTION DEVICE
Item 1. Fan Switch
Item 2. Gas Button
Item 3. Igniter Button