background image

© 2014 STANLEY Black & Decker, Inc.

New Britain, CT 06053

U.S.A.

62213 8/2018 Ver. 8

USER MANUAL 

Safety, Operation and Maintenance

DR19

HYDRAULIC 

DIGGER

Summary of Contents for DR19

Page 1: ...2014 STANLEY Black Decker Inc New Britain CT 06053 U S A 62213 8 2018 Ver 8 USER MANUAL Safety Operation and Maintenance DR19 HYDRAULIC DIGGER...

Page 2: ......

Page 3: ...d select the Company tab Warranty Note The warranty validation record must be submitted to validate the warranty SERIOUS INJURY OR DEATH COULD RESULT FROM THE IMPROPER REPAIR OR SERVICE OF THIS TOOL R...

Page 4: ...ntially hazardous situation which if not avoided could result in death or serious injury This signal word indicates a potentially hazardous situation which if not avoided may result in property damage...

Page 5: ...daily Never operate the tool if you cannot be sure that underground utilities are not present Never wear loose clothing or unrestrained long hair that can get entangled in the working parts of the too...

Page 6: ...RN OR DAMAGED HOSE 3 MAKE SURE HYDRAULIC HOSES ARE PROPERLY CON NECTED TO THE TOOL BEFORE PRESSURING SYSTEM SYSTEM PRESSURE HOSE MUST ALWAYS BE CON NECTED TO TOOL IN PORT SYSTEM RETURN HOSE MUST ALWAY...

Page 7: ...TH TO REMOVE DIRT AND MOISTURE AND TEST HOSE FOR MAXIMUMALLOWABLE CURRENT LEAKAGE INACCORDANCE WITH SAFETY DEPARTMENT INSTRUCTIONS SEE OTHER SIDE SIDE 2 D O N O T R E M O V E T H I S T A G 3 DO NOT EX...

Page 8: ...175 1 25 4 Return 2500 175 13 16 49 60 up to 25 up to 8 5 8 16 Pressure 2500 175 3 4 19 Return 2500 175 13 16 49 60 26 100 8 30 3 4 19 Pressure 2500 175 1 25 4 Return 2500 175 Figure 1 Typical Hose C...

Page 9: ...operator discomfort at the tool Filter minimum full flow filtration 25 microns 25 microns 25 microns 25 microns Sized for flow of at least For cold temp startup and maximum dirt holding capacity 30 GP...

Page 10: ...locked position Note the orientation of the particular tool bit that is being installed CONNECT HOSES 1 Wipe all hose couplers with a clean lint free cloth before making connections 2 Connect the hos...

Page 11: ...l seals Always replace hoses couplings and other parts with replacement parts recommended by STANLEY Supply hoses must have a minimum working pressure rating of 2500 psi 172 bar Donotexceedtheratedflo...

Page 12: ...05 140 bar Couplers or hoses blocked Remove restriction Pressure and return line hoses reversed at ports Be sure hoses are connected to their proper ports Mechanical failure of piston or internal part...

Page 13: ...lbs 10 9 kg Pressure Range 1500 2000 psi 105 140 bar Flow Range 7 9 GPM 26 34 LPM Optimum Flow 8 GPM 30 LPM Porting 3 8 male pipe hose end Length 20 inches 51 cm System Type Open Center Accessory Shan...

Page 14: ...14 DR19 User Manual DR19 PARTS ILLUSTRATION...

Page 15: ...RSING SPOOL 23 00211 2 O RING 1 1 1 8 1 16 24 03254 1 VALVE GLAND 25 01772 1 O RING 3 4 7 8 1 16 26 02454 4 ALLEN NUT INCL WITH ITEM 21 27 02177 1 O RING 2 1 16 2 1 4 3 32 28 02865 1 BACK UP RING 29 0...

Page 16: ...STANLEY Infrastructure 6430 SE Lake Road Portland Oregon 97222 USA 503 659 5660 Fax 503 652 1780 www stanleyinfrastructure com...