Always observe safety symbols. They are included for your safety and for the protection of the tool. 

LOCAL SAFETY REGULATIONS

Enter  any  local  safety  regulations  here.    Keep  these  instructions  in  an  area  accessible  to  the  operator  and 

maintenance personnel.

Safety symbols and signal words, as shown below, are used to emphasize all operator, maintenance and repair 

actions which, if not strictly followed, could result in a life-threatening situation, bodily injury or damage to equipment.

This is the safety alert symbol. It is used to alert you to potential personal injury 

hazards.  Obey all  safety messages  that follow  this symbol  to avoid  possible 

injury or death.
This safety alert and signal word indicates an imminently hazardous situation 

which, if not avoided, will

 result in 

death or serious injury

.

This  safety  alert  and  signal  word  indicates  a  potentially  hazardous  situation 

which, if not avoided, 

could result in 

death or serious injury

.

This  safety  alert  and  signal  word  indicates  a  potentially  hazardous  situation 

which, if not avoided, 

could result in 

death or serious injury

.

This signal word indicates a potentially hazardous situation which, if not avoided, 

may result in property damage.

This signal word indicates a situation which, if not avoided, will

 result in damage 

to the equipment

.

This signal word indicates a situation which, if not avoided, 

may result in damage 

to the equipment

.

Tool operators and maintenance personnel must comply with safety precautions given in this manual, and on the 

stickers and tags attached to or on the tool and hoses.
These precautions are for your safety. Review them carefully before operating the tool or performing any maintenance 

or repairs.

Supervising personnel may specify additional precautions for your work area to comply with company policies and 

local safety regulations. Enter added precautions in the space provided in this manual.

The DR19 Hydraulic Digger will provide safe, dependable service if operated in accordance with the instructions 

given in this manual. Read and understand the manual any decals, labels, or tags attached to the tool and hoses. 

Failure to do so can cause serious personal injury or damage to the equipment.

SAFETY SYMBOLS

Summary of Contents for DR19

Page 1: ...2014 STANLEY Black Decker Inc New Britain CT 06053 U S A 62213 8 2018 Ver 8 USER MANUAL Safety Operation and Maintenance DR19 HYDRAULIC DIGGER...

Page 2: ......

Page 3: ...d select the Company tab Warranty Note The warranty validation record must be submitted to validate the warranty SERIOUS INJURY OR DEATH COULD RESULT FROM THE IMPROPER REPAIR OR SERVICE OF THIS TOOL R...

Page 4: ...ntially hazardous situation which if not avoided could result in death or serious injury This signal word indicates a potentially hazardous situation which if not avoided may result in property damage...

Page 5: ...daily Never operate the tool if you cannot be sure that underground utilities are not present Never wear loose clothing or unrestrained long hair that can get entangled in the working parts of the too...

Page 6: ...RN OR DAMAGED HOSE 3 MAKE SURE HYDRAULIC HOSES ARE PROPERLY CON NECTED TO THE TOOL BEFORE PRESSURING SYSTEM SYSTEM PRESSURE HOSE MUST ALWAYS BE CON NECTED TO TOOL IN PORT SYSTEM RETURN HOSE MUST ALWAY...

Page 7: ...TH TO REMOVE DIRT AND MOISTURE AND TEST HOSE FOR MAXIMUMALLOWABLE CURRENT LEAKAGE INACCORDANCE WITH SAFETY DEPARTMENT INSTRUCTIONS SEE OTHER SIDE SIDE 2 D O N O T R E M O V E T H I S T A G 3 DO NOT EX...

Page 8: ...175 1 25 4 Return 2500 175 13 16 49 60 up to 25 up to 8 5 8 16 Pressure 2500 175 3 4 19 Return 2500 175 13 16 49 60 26 100 8 30 3 4 19 Pressure 2500 175 1 25 4 Return 2500 175 Figure 1 Typical Hose C...

Page 9: ...operator discomfort at the tool Filter minimum full flow filtration 25 microns 25 microns 25 microns 25 microns Sized for flow of at least For cold temp startup and maximum dirt holding capacity 30 GP...

Page 10: ...locked position Note the orientation of the particular tool bit that is being installed CONNECT HOSES 1 Wipe all hose couplers with a clean lint free cloth before making connections 2 Connect the hos...

Page 11: ...l seals Always replace hoses couplings and other parts with replacement parts recommended by STANLEY Supply hoses must have a minimum working pressure rating of 2500 psi 172 bar Donotexceedtheratedflo...

Page 12: ...05 140 bar Couplers or hoses blocked Remove restriction Pressure and return line hoses reversed at ports Be sure hoses are connected to their proper ports Mechanical failure of piston or internal part...

Page 13: ...lbs 10 9 kg Pressure Range 1500 2000 psi 105 140 bar Flow Range 7 9 GPM 26 34 LPM Optimum Flow 8 GPM 30 LPM Porting 3 8 male pipe hose end Length 20 inches 51 cm System Type Open Center Accessory Shan...

Page 14: ...14 DR19 User Manual DR19 PARTS ILLUSTRATION...

Page 15: ...RSING SPOOL 23 00211 2 O RING 1 1 1 8 1 16 24 03254 1 VALVE GLAND 25 01772 1 O RING 3 4 7 8 1 16 26 02454 4 ALLEN NUT INCL WITH ITEM 21 27 02177 1 O RING 2 1 16 2 1 4 3 32 28 02865 1 BACK UP RING 29 0...

Page 16: ...STANLEY Infrastructure 6430 SE Lake Road Portland Oregon 97222 USA 503 659 5660 Fax 503 652 1780 www stanleyinfrastructure com...