Page 14
Radar Installation Manual
Radar Cable
Radar On/Off Switch
(Green & Blue wires
from Radar Cable)
Power / Data
Swiched
DC Power
GPS Chart
CP300
WAAS
Figure 2.4 - Example of Connection Procedure for CP300
2.5
RADAR JUNCTION BOX CONNECTIONS
Referring to the diagram below, connect the color coded wires from the Radar cable to the
designated place on Terminal strip A in Radar Junction Box as follows.
TERMINAL C
Radar Cable
5. Connect the BLUE and
GREEN wires from the
Radar cable a Single Pole
Single Throw (SPST) switch.
This switch is used to turn
the Radar On and Off.
TERMINAL A
Chart Plotter
TERMINAL B
Power Supply
MOUNTING INSTRUCTIONS
1. Open the box unscrewing the
4 bottom screws.
2. Connect the Chart Plotter to
terminal A.
3. Connect the Power Supply to
terminal B.
4. Connect the
to
terminal C.
Radar Cable
Note:
No connections are
made to Switch (1) & Switch (2)
Figure 2.5 - Radar Junction Box
Terminal Strip A - Chart Plotter
This terminal strip is used to connect a compatible Standard Horizon GPS Chart Plotter to
a Radar Antenna. Power – and Power+ connections are used to power the Standard
Horizon Chart Plotter when connected.
Terminal Strip B - Power Supply
This terminal strip is used to connect the proper supply to power the Radar Antenna and