Page 19
MAINTENANCE MODE - LCD
Maintenance Mode allows access to service and diagnostic information, as well as provides the ability to adjust certain
program default parameters. To enter Maintenance Mode:
1. Press and hold the
, and keys together.
2. A beep will sound and “MAINTENANCE MODE” will display momentarily in the Information Window.
3. Release all keys. “SERIAL NO #####” will display in the Information Window.
The following keys are available in MAINTENANCE MODE:
NOTE: To exit Maintenance Mode without saving any values or settings, press the QUICK START key.
A complete list of the items that you may display and change in Maintenance Mode:
Increase and Decrease LEVEL Keys: Adjust the value of the displayed parameter up and down, respectively, in
increments of 1 unit. These keys do not save the new value - see OK Key below.
Numeric Keypad: Allows you to enter specific values for numeric parameters. These keys do not save the new
value - see OK Key below.
OK Key: Updates (saves) the values of all parameters in non-volatile memory, and exits Maintenance Mode.
Item
Min
Max
Default
Notes
SW VERSION
01.00
99.99
N/A
Display software version (set by factory)
LCB VERSION
01.01
99.99
N/A
Load Control Board software version
(set by factory)
SERIAL #
0
65535
N/A
Serial number (set by factory)
RUN HRS
0
65535
N/A
Total operating hours
MAINT HRS
0
9999
N/A
Total operating hours since last reset
FLOORS
0
65535
N/A
Total floors climbed
UNITS (ENGLISH/METRIC)
English
Metric
English
English = pounds, feet; Metric = kilograms,
meters
DEFAULT TIME (5-180)
5
180
120
Default time used by programs