Stahlwille MANOSKOP 721 Quick Instructions For Use Manual Download Page 16

Cleaning 

 

 

16 

 

Proceed as follows: 

 

Remove the two plugs using a sharp object. 
Retain the plugs for later use. 

  

 

  

 

To adjust the lower end of the range, insert the 
Allen key in the hole nearer to the handle. 
To adjust the lower end of the range, insert the 
Allen key in the other hole. 

 

Turn the Allen key with great care and very 
slowly. Turning in a clockwise direction increases 
the cut-out torque level, turning in the other 
direction decreases it. The screws will lock in any 
position. 

  

 

  

 

Once you have made an adjustment using one 
screw, check the effect by testing the cut-out 
value on the torque tester. 

 

Repeat the adjustment of one or both screws and 
the testing process until the deviation has been 
compensated. 

 

Finally, do a thorough test again. Proceed as 
described under „Checking the accuracy of the 
cut-out value“. 

  

If you cannot achieve adequate correspondence 
between the triggering values and the set values in 
this way, the triggering mechanism is probably 
defective. 
Consult STAHLWILLE if this occurs. 

  

 

Replace the plugs as appropriate to protect the 
cut-out mechanism against dirt and damp. 
Replacement plugs are available from 
STAHLWILLE. 

  

 

  

Cleaning 

Clean the MANOSKOP

®

 only with white Spirit. 

Other chemical substances may damage the plastic 
components. 

  

Summary of Contents for MANOSKOP 721 Quick

Page 1: ...Instructions for use EN MANOSKOP 721 730 Quick Status 07 2016...

Page 2: ...amage 6 Correct torque settings 7 Operation 7 Selecting the inserts and insert tools 8 Attaching insert tools 8 721 5 721 15 721 20 721QR 20 Quick 8 721 30 Quick 9 Attaching insert tools 730 5 to 730...

Page 3: ...ntil the wrench cuts out After use it does not need to be reset to the lowest value As soon as the torque wrench is released it is ready for the next job The 2 component grip which is ergonomically de...

Page 4: ...et with a push through 12 5 1 2 square drive Service MANOSKOP 730 5 to 730 65 Quick can be fitted with various insert tools For this purpose the head of the wrench has a recessed square drive at the f...

Page 5: ...10 functional length LF mm 288 288 343 343 390 390 standard extension SF mm 17 5 17 5 17 5 17 5 25 25 weight g 805 805 965 965 1100 1100 730 20 730a 20 730 40 730 65 730 II 65 range N m ft lb in lb 40...

Page 6: ...ded purpose The buyer and user are responsible for any damage or injury resulting from non adherence to these instructions MANOSKOP 721 and 730 Quick have not been designed for tightening of screw joi...

Page 7: ...rst The period 12 months starts with the initial commissioning If an inspection shows that there is excessive deviation the torque wrench will have to be readjusted see page 15 Operation MANOSKOP 721...

Page 8: ...nsultation with STAHLWILLE CAUTION Unsecured plug in tools lead to a risk of injury Make sure that plug in tools are always secured against pulling out by engaging the retaining pin Remember that the...

Page 9: ...rive until it locates Attaching insert tools 730 5 to 730 65 Quick Insert the insert tool into the internal square drive on the face of the head of the wrench The spring loaded locking pin of the inse...

Page 10: ...vel The torque level at which the wrench cuts out is set by moving the scale against the fixed mark Always approach the desired torque setting from a lower value Intermediate settings between two mark...

Page 11: ...which is pushed through For controlled counter clockwise tightening using the MANOSKOP 721 30 Quick in the turned over position the square drive must first be pushed through to the upper side For cont...

Page 12: ...the workpiece Actuate the MANOSKOP via the handle only Grip the handle centrally Tighten at a tangent to the slewing radius and at an angle to the tightening axis Pull steadily and without any interr...

Page 13: ...s an accuracy of 1 of the displayed value or better If you have access to such a tester you may inspect the MANOSKOP yourself Suitable torque testers are available from STAHLWILLE It is also possible...

Page 14: ...1 value set on the Manoskop W2 tester measured value Set the torque wrench to the highest scale reading Use this setting to perform five measurements on the torque tester Use the following formula to...

Page 15: ...eadjustment each MANOSKOP is equipped with two internal adjuster screws These are accessible with an Allen key size 2 mm through two holes in the housing The screw which is closest to the end of the h...

Page 16: ...ew check the effect by testing the cut out value on the torque tester Repeat the adjustment of one or both screws and the testing process until the deviation has been compensated Finally do a thorough...

Page 17: ...en ring insert tools Torx insert tools Bit holder insert tools For inspection and readjustment purposes Mechanical torque testers Electronic torque testers Services repairs testing and readjusting inc...

Page 18: ...STAHLWILLE Eduard Wille GmbH Co KG Lindenallee 27 42349 Wuppertal Germany Tel 49 202 4791 0 Fax 49 202 4791 200 support stahlwille de www stahlwille de...

Reviews: