Intended Use

4

205582 / 8581615300

2014-10-10·BA00·III·en·03

SolConeX Switch Socket, 125 A 
8581/31

Observe the following information during installation and operation:

Any damage can invalidate the explosion protection

National and local safety regulations

National and local accident prevention regulations

National and local assembly and installation regulations (e.g. IEC/EN 60079-14)

Generally recognized technical regulations

Safety instructions in these operating instructions

Characteristic values and rated operating conditions on the rating and data plates

Additional instruction plates fixed directly to the device

3.2 Modifications and alterations

3.3 Special Versions

For special versions, the actual components included in delivery may differ from the de-
scription given here in the following cases:

X

additional/different order options

X

modifications to the versions described here due to the latest technical developments

4

Intended Use

The switch sockets 8581/31 are explosion-protected equipment approved for use in haz-
ardous areas of Zones 1, 2 and 21, 22. They connect portable and fixed electrical equip-
ment as well as cables and circuits in hazardous areas.

 WARNING

Alterations and modifications to the device are not permitted.

We shall not accept any liability or warranty obligations for damage resulting 
from unauthorized alterations and modifications.

Summary of Contents for SolConeX8581/31

Page 1: ...Operating instructions SolConeX Switch Socket 125 A 8581 31...

Page 2: ...2 Installation Conditions 9 7 3 Opening Closing the Enclosure 11 7 4 Mounting and Operating Position 11 7 5 Electrical Connection 11 7 6 Connection 12 8 Auxiliary Contacts 12 8 1 Mounting Auxiliary Co...

Page 3: ...installation place For correct operation please observe all other operating instructions enclosed in this delivery and the operating instructions of the equipment to be connected Safety Instructions N...

Page 4: ...lates fixed directly to the device 3 2 Modifications and alterations 3 3 Special Versions For special versions the actual components included in delivery may differ from the de scription given here in...

Page 5: ...auxiliary contacts for Ex i circuits E II 2 D Ex tD A21 ib IP66 T65 C Ta 30 40 C E II 2 D Ex tD A21 ib IP66 T75 C Ta 30 45 C Certificates IECEx IECEx PTB 06 0034 Europe ATEX PTB 01 ATEX 1161 Ambient...

Page 6: ...5 x 1 5 1 x M63 x 1 5 Enclosure material polyester glass fibre reinforced Degree of protection IP66 acc to IEC EN 60529 Auxiliary contacts Standard version 8080 1 1 1 NC contact 1 NO contact in left i...

Page 7: ...The devices must be stored in a dry place and vibration free 06556E00 06555E00 3 P PE 8581 31 4 3P N PE 8581 31 5 No of poles Frequency Rated operational voltage Colour code Earth contact sleeve posit...

Page 8: ...f electric shock Before opening the device disconnect it from the power supply WARNING Use approved components only For unused enclosure holes use R STAHL stopping plugs for unused cable entries use R...

Page 9: ...able washers all screws and nuts have been firmly tightened 7 5 Electrical Connection The information given in chapter Technical Data must be observed The conductor connection must be made with partic...

Page 10: ...d 1 NO contact in the left installation slot A maximum of 2 Type 8080 1 auxiliary contacts can be used The switching function of the auxiliary contact depends on the installation slot used see chapter...

Page 11: ...enclosed circuit diagram indicating the respective switching function to the rating plate of the switch 8 2 Dismounting Auxiliary Contacts Introduce the auxiliary contact key art no 201909 with the St...

Page 12: ...e that no components are damaged the device has been installed according to regulations there are no foreign bodies inside the device all screws and nuts have been firmly tightened the prescribed tigh...

Page 13: ...hort circuit in the Main Circuit 11 Cleaning The device may only be cleaned with a damp cloth 12 Disposal Observe the national waste disposal regulations NOTICE Switching on and off has to be done swi...

Page 14: ...iary contact series 8080 1 12446E00 2 NC contacts 8080 1 3 2 168356 0 026 1 NC contact 1 NO contact 8080 1 1 1 168351 0 026 2 NO contacts 8080 1 4 2 168353 0 026 The switching function of the auxiliar...

Reviews: