![Stahl SolConeX8581/31 Operating Instructions Manual Download Page 13](http://html1.mh-extra.com/html/stahl/solconex8581-31/solconex8581-31_operating-instructions-manual_1357600013.webp)
205582 / 8581615300
2014-10-10·BA00·III·en·03
Maintenance, Overhaul and Repair
13
SolConeX Switch Socket, 125 A 8581/
31
9.1 Padlocking with a Padlock
The switch can be padlocked in position 0 and I.
10 Maintenance, Overhaul and Repair
The following details must be checked during maintenance:
Cables are held securely in place
Compliance with the permitted temperatures (according to IEC/EN 60079)
Damage to the enclosure and seals
Check if screws and nuts are tight.
10.1 Short-circuit in the Main Circuit
11 Cleaning
The device may only be cleaned with a damp cloth.
12 Disposal
Observe the national waste disposal regulations.
NOTICE
Switching on and off has to be done swiftly and completely!
Avoid switching positions between 0 and I (ON and OFF)!
WARNING
Risk of electric shock!
Before opening the device, disconnect it from the power supply.
NOTICE
To avoid corrosion, the plug must be pulled regularly.
WARNING
After a short-circuit in the main circuit, the switch must be replaced!
Replace the switch after each short circuit in the main circuit, since with hermet-
ically sealed equipment the state of the switching contacts cannot be checked.