Operating Instructions MT-xx6-A
Permitted maximum values
Page 20 of 60
R. STAHL HMI Systems GmbH / OI_MT_xx6_A_en_V_03_00_26.docx / 03.11.2020
Reader RSi1 (power supply reader, X8.3-4):
U
o
=
5.36
V
l
o
=
220
mA
P
o
=
1.18
W
a)
The maximum values for zone 1 group IIC are:
C
i
=
5.3
µF
C
o
=
40.7
59.7
µF
L
i
=
0
mH
L
o
=
2
1
µH
C
o
and L
o
pairs directly above/underneath each other may be used.
The maximum values for zone 1 group IIB are:
C
i
=
5.3
µF
C
o
=
70.7
124.7
µF
L
i
=
0
mH
L
o
=
2
1
µH
C
o
and L
o
pairs directly above/underneath each other may be used.
b)
The maximum values for zone 2 group IIC are:
C
i
=
5.3
µF
C
o
= 124.7 994.7
mF
L
i
=
0
mH
L
o
=
2
1
µH
C
o
and L
o
pairs directly above/underneath each other may be used.
The maximum values for zone 2 group IIB are:
C
i
=
5.3
µF
C
o
= 154.7 324.7
µF
L
i
=
0
mH
L
o
=
20
10
µH
C
o
and L
o
pairs directly above/underneath each other may be used.
Reader RSi1 and RSi2 (signal input / output, X8.5-8):
U
i
=
15
V
U
o
=
5.36
V
I
i
=
500
mA
I
o
=
46
mA
P
i
=
2.5
W
P
o
=
62
mW
a)
The maximum values for zone 1 group IIC are:
C
i
=
0
µF
C
o
=
46
µF
L
i
=
0
mH
L
o
=
2
µH
C
o
and L
o
pairs directly above/underneath each other may be used.
The maximum values for zone 1 group IIB are:
C
i
=
0
µF
C
o
=
79
µF
L
i
=
0
mH
L
o
=
20
µH
C
o
and L
o
pairs directly above/underneath each other may be used.
b)
The maximum values for zone 2 group IIC are:
C
i
=
0
µF
C
o
=
130
µF
L
i
=
0
mH
L
o
=
2
µH
C
o
and L
o
pairs directly above/underneath each other may be used.
The maximum values for zone 2 group IIB are:
C
i
=
0
µF
C
o
=
160
µF
L
i
=
0
mH
L
o
=
20
µH
C
o
and L
o
pairs directly above/underneath each other may be used.