Operating Instructions MT-xx7
Operation
R. STAHL HMI Systems GmbH / OI_MT_xx7_en_V_01_02_14.docx / 06.12.2019
Page 29 of 44
12 Operation
12.1 General information
When operating the devices, particular care shall be taken that:
the HMI device has been properly installed according to
instructions,
the HMI device is undamaged,
the terminal compartment is clean,
all screws are tightened fast,
before switching the HMI device on, its external equipotential
bonding terminal is properly connected to the equipotential
bonding system at its place of use,
the cover of the terminal compartment is completely closed.
12.2 Connections
Terminal
Pin
Definition / typical cable color
Connection
X10
1
Power supply HMI 24 VDC or 100 - 240 VAC
Power supply
PWR
2
Power supply HMI device 0 VDC or 100 - 240 VAC
of the HMI device
3
Earth connection
Ex nA
X11
1
+UB
Red
USB interface
KBi
2
D-
White
Ex ia
3
D+
Green
for
4
GND
Black
External keyboard
X12
1
+UB
Red
USB interface
Mi
2
D-
White
Ex ia
3
D+
Green
for
4
GND
Black
Mouse
X13
1
+UB
Red
USB Ex nA
2
D-
White
3
D+
Green
4
GND
Black
X14
1
+12 V
Red
12 VDC output
2
GND
Black
Ex nA, max. 500 mA
X16
TX
2TX
TX
2TX
Ethernet copper
CAT7 /
1
TRD0+
TxD + 1
White / Orange White / Orange 1
TX1
connection *
CAT5
2
TRD0-
TxD - 1
Orange
Orange 1
Ex nA
Data
3
TRD1+
RxD + 1
White / Green
White / Green 1
either *
4
TRD1-
RxD - 1
Green
Green 1
TX or 2TX
5
TRD2+
TxD + 2
Blue / White
White / Orange 2
TX2
6
TRD2-
TxD - 2
Blue
Orange 2
7
TRD3+
RxD + 2
White / Brown
White / Green 2
8
TRD3-
RxD - 2
Brown
Green 2
(2TX not
9
SHLD
SHLD
Screen
Screen
600 SERIES)
X18
FO 1
Data
Optical fibre connection type LC
Duplex connector
Ethernet optical fibre
interface *
Ex op is
Tx Rx
NOTICE