154099 / 8591601300
S-BA-8591-04-en-04/09/2009
Installation
21
Ex Plug Connector miniClix
8591/1, 8591/4
X
Loosen the locking screw (1).
X
Screw the pressure fitting (2) out of the plug/coupler sleeve (7).
X
Screw out the individual parts 3-6.
X
Guide the stripped wire through the pressure fitting, the strain-relief (3), the seal ring
(4) and the pressure washer/shield (5).
X
Connect the connecting cable as described above.
11389E00
X
Align and insert the plug insert (6) correctly into the plug/coupler sleeve (7).
X
Insert the pressure washer/shield (5), the seal ring (4) and the strain-relief (3) in the
plug sleeve (7).
X
Screw on the pressure fitting and then secure it in place using the locking screw (1).
11387E00
Fig.: Plug
11388E00
Fig.: Coupler
WARNING
Threads can be damaged by screwing on at an angle!
X
Exercise care (straight alignment) when inserting and screwing on all components.