background image

916260330020

2018-03-08·HB00·III·en·02

General Information 

3

EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN

Transmitter Supply Unit with Limit Values

Series 9162

1

General Information

1.1

Manufacturer

R. STAHL Schaltgeräte GmbH

Am Bahnhof 30

74638 Waldenburg 

Germany

Phone: +49 7942 943-0

Fax:

+49 7942 943-4333

Internet: www.stahl-ex.com

E-Mail: [email protected]

1.2

Information about the manual

ID-No.:

916260330020

Publication Code:

2018-03-08·HB00·III·en·02

Hardware version:

C

Software version:

V01-06

Configuration software ISpac Wizard 3.04.00 or subsequent versions

The original instructions are the English edition.

They are legally binding in all legal affairs.

1.3

Further documents

• Cabinet installation guide

• Brief instructions for module parameterising with ISpac Wizard  

(see ISpac Wizard software)

• FMEDA report

• Safety manual 9162

• Data sheet 9162 Ex i

• Data sheet 9162

• Operating instructions 9162

For further languages, see www.stahl-ex.com.

1.4

Conformity with standards and regulations

See certificates and EC Declaration of Conformity: www.stahl-ex.com.

The device has IECEx approval. See IECEx homepage: http://iecex.iec.ch/

Further national certificates can be downloaded via the following link:  

http://www.r-stahl.com/downloads/certificates.html.

Summary of Contents for 9162 Series

Page 1: ...EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Manual Additional languages www stahl ex com EN Transmitter Supply Unit with Limit Values Series 9162...

Page 2: ...2 Safe use 5 3 3 Modifications and alterations 6 4 Function and device design 7 4 1 Function 7 4 2 Device design 7 5 Technical data 8 6 Engineering 12 7 Transport and storage 12 8 Mounting and install...

Page 3: ...ion software ISpac Wizard 3 04 00 or subsequent versions The original instructions are the English edition They are legally binding in all legal affairs 1 3 Further documents Cabinet installation guid...

Page 4: ...e of danger damage Consequences of danger Taking countermeasures to avoid the danger or damage Symbol Meaning Tips and recommendations on the use of the device General danger Danger due to explosive a...

Page 5: ...L Schaltger te GmbH if using the device under operating conditions which are not covered by the technical data Observe the document Cabinet installation guide for engineering download from www stahl e...

Page 6: ...e must be discharged on earthed metal parts or an ESD wrist strap must be put on Connect the device only to equipment which does not carry voltages higher than 253 V AC 50 Hz Ensure that there is a di...

Page 7: ...g values can be defined with which the analog input signal is compared Exceeding or falling below the limiting values controls the electrical contacts The device can transmit a superimposed HART commu...

Page 8: ...ons and certificates Certificates IECEx ATEX Canada cFM USA FM Safety data When connecting transmitters When connecting current sources 2 wire transmitter 3 wire transmitter max voltage Uo 27 V 27 V m...

Page 9: ...nC IIC T4 Gc Europe ATEX Gas BVS 15 ATEX E017X E II 3 G Ex nA nC IIC T4 Gc Certifications and certificates Certificates IECEx ATEX Canada cFM USA FM Technical Data Electrical data Auxiliary power Nom...

Page 10: ...mpedance HART 250 Input resistance for mA sources 30 Communication signal bidirectional HART transmission 0 5 10 kHz in 2 wire transmitters Output Output signal 4 20 mA with HART Load resistance RL 0...

Page 11: ...Behaviour of the output Input signal Ambient conditions Ambient temperature Single device 40 70 C Group assembly 40 60 C The installation conditions affect the ambient temperature Observe the Cabinet...

Page 12: ...3621E01 Technical Data Mechanical data Connection NOTE Explosion hazard due to too high temperature in the cabinet Non compliance results in severe or fatal injuries Install and adjust the cabinet in...

Page 13: ...alled in an enclosure which fulfils the requirements of IEC EN 60079 15 or IEC EN 60079 31 DANGER Explosion hazard due to incorrect installation of the device Non compliance results in severe or fatal...

Page 14: ...7391E00 Engage the pac Bus elements on the top hat rail 15551E00 Connect the terminal set at the beginning and at the end 06886E00 Position the device on the top hat rail Position the cut out of the e...

Page 15: ...le channel devices remove the covering in terminal slot 2 between the black and the green terminal 15569E00 Position the device on the pac Carrier Place the cut out of the enclosure on the outside edg...

Page 16: ...mation and instructions on this can be obtained from your regional sales contact on request DANGER Explosion hazard caused by too high voltage Non compliance results in severe or fatal injuries Connec...

Page 17: ...ws at the terminals Correct tightening torque 0 5 0 6 Nm 2 wire transmitter 3 wire transmitter mA source 15539E00 15540E00 15541E00 9162 Channel 1 17251E00 A load resistance of at least 250 Ohm is nec...

Page 18: ...ut for exception refer to chapter Anti pumping device 9 2 2 Anti pumping device If a limiting value is reached the anti pumping device ensures that the limit contact remains in working position OFF ev...

Page 19: ...t setting function is off Activated Function as described above When the event occurs the set operating mode OFF does not change The anti pumping device is reset by actuating the DIP switch RL OFF ON...

Page 20: ...ce The device does not require regular maintenance 11 3 Repair 11 4 Returning the device Use the Service form to return the device if repair or service is required On the internet site www stahl ex co...

Page 21: ...not use aggressive detergents or solvents 13 Disposal Observe national and local regulations and statutory regulation regarding disposal Separate materials when sending it for recycling Ensure environ...

Reviews: