Mounting and Installation
8
143672 / 8295601300
2015-09-23·BA00·III·en·02
Adaptors and reducers made of metal
Series 8295
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
7.2
Mounting / Dismounting, Operating Position
• Fasten the components by means of metal nuts.
• Secure the components against twisting and loosening.
Dimensional Drawings (All Dimensions in mm [inches]) – Subject to Alterations
Version
External thread d1
Internal thread d2
Dimensions
A/F
Reducer
metric / metric
04533E00
M20 x 1.5
M16 x 1.5
27
M25 x 1.5
M16 x 1.5
32
M25 x 1.5
M20 x 1.5
32
M32 x 1.5
M20 x 1.5
41
M32 x 1.5
M25 x 1.5
41
M33 x 1.5
M24 x 1.5
41
M40 x 1.5
M32 x 1.5
50
M48 x 1.5
M42 x 1.5
55
M50 x 1.5
M40 x 1.5
60
M56 x 1.5
M42 x 1.5
56
M56 x 1.5
M48 x 1.5
65
M63 x 1.5
M50 x 1.5
75
M75 x 1.5
M63 x 1.5
85
M90 x 1.5
M75 x 1.5
100
During installation note that the wall surface as well as the components
should be kept clean, even (parallel) and grooveless in order to ensure the
IP protection.